Comparison of functional residual capacity and static compliance of the respiratory system during a positive end-expiratory pressure (PEEP) ramp procedure in an experimental model of acute respiratory distress syndrome

نویسندگان

  • Bernard Lambermont
  • Alexandre Ghuysen
  • Nathalie Janssen
  • Philippe Morimont
  • Gary Hartstein
  • Paul Gerard
  • Vincent D'Orio
چکیده

INTRODUCTION Functional residual capacity (FRC) measurement is now available on new ventilators as an automated procedure. We compared FRC, static thoracopulmonary compliance (Crs) and PaO2 evolution in an experimental model of acute respiratory distress syndrome (ARDS) during a reversed, sequential ramp procedure of positive end-expiratory pressure (PEEP) changes to investigate the potential interest of combined FRC and Crs measurement in such a pathologic state. METHODS ARDS was induced by oleic acid injection in six anesthetised pigs. FRC and Crs were measured, and arterial blood samples were taken after induction of ARDS during a sequential ramp change of PEEP from 20 cm H2O to 0 cm H2O by steps of 5 cm H2O. RESULTS ARDS was responsible for significant decreases in FRC, Crs and PaO2 values. During ARDS, 20 cm H2O of PEEP was associated with FRC values that increased from 6.2 +/- 1.3 to 19.7 +/- 2.9 ml/kg and a significant improvement in PaO2. The maximal value of Crs was reached at a PEEP of 15 cm H2O, and the maximal value of FRC at a PEEP of 20 cm H2O. From a PEEP value of 15 to 0 cm H2O, FRC and Crs decreased progressively. CONCLUSION Our results indicate that combined FRC and Crs measurements may help to identify the optimal level of PEEP. Indeed, by taking into account the value of both parameters during a sequential ramp change of PEEP from 20 cm H2O to 0 cm H2O by steps of 5 cm H2O, the end of overdistension may be identified by an increase in Crs and the start of derecruitment by an abrupt decrease in FRC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of functional residual capacity and static compliance of the respiratory system during a PEEP ramp procedure in an experimental model of acute respiratory distress syndrome

Introduction: Functional residual capacity (FRC) measurement is now available on new ventilators as an automated procedure. We compared FRC, static thoraco-pulmonary compliance (Crs) and PaO2 evolution in an experimental model of acute respiratory distress syndrome (ARDS) during a reversed, sequential ramp procedure of positive end-expiratory pressure (PEEP) changes to investigate the potential...

متن کامل

Respiratory mechanics in patients ventilated for critical lung disease.

Respiratory mechanics, using flow interruption, was previously studied during the complete breath in healthy ventilated man, numerical techniques relieving constraints regarding flow pattern. The classical linear model of non-Newtonian behaviour was found to be valid. The present study was extended to subjects with critical lung disease. Subjects with acute lung injury (ALI; n = 2), acute respi...

متن کامل

Respiratory mechanics and lung stress/strain in children with acute respiratory distress syndrome

BACKGROUND In sedated and paralyzed children with acute respiratory failure, the compliance of respiratory system and functional residual capacity were significantly reduced compared with healthy subjects. However, no major studies in children with ARDS have investigated the role of different levels of PEEP and tidal volume on the partitioned respiratory mechanic (lung and chest wall), stress (...

متن کامل

Comparison of the Effect of Manual and Ventilator Hyperinflation on Static Lung Compliance in Mechanically Ventilated Patients with Pulmonary Acute Lung Injury/ ARDS

Submit Manuscript | http://medcraveonline.com Abbreviations: ALI: Acute Lung Injury; ARDS: Acute Respiratory Distress Syndrome; PEEP: Positive End Expiratory Pressure; CST: Static Lung Compliance; MHI: Manual Hyperinflation; VHI: Ventilator Hyperinflation; MABP: Mean Arterial Blood Pressure; HR: Heart Rate Pulse Oximetric Saturation (SpO2) S/F ratio: Ratio Fraction of Inspired Oxygen (FiO2) Int...

متن کامل

Response of Maximum Inspiratory Pressure and Functional Capacity to Positive End-Expiratory Pressure Device after Valvular Heart Surgery

Background: Pulmonary complications following valvular heart surgery are common and contribute to increased duration of hospital stay, rate of morbidity, and mortality. The purpose of the present study was to investigate the response of maximum inspiratory pressure and functional capacity to Positive End-Expiratory Pressure device in patients who underwent valvular hea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Critical Care

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2008