Intra-aortic balloon pumping in infants and children.
نویسندگان
چکیده
From November 1981 to November 1982, intra-aortic balloon pumping (IABP) was used after surgery in eight patients who were from 6 weeks to 6 years old and who weighed from 4.2 to 16.2 kg. In seven patients, specially constructed intra-aortic balloons with 2.5 and 5.0 ml volumes mounted on No. 5F catheters were used. In the largest and oldest patient, a two-chamber 10 ml balloon was used. The pumping module used was the Datascope System 82. Effective diastolic augmentation of arterial pressure was accomplished in seven of the eight patients and suprasystolic diastolic augmentation was accomplished in four. The two youngest and smallest patients are the only long-term survivors. There were two short-term survivors who died 5 and 10 days after successful IABP. In only one patient was there no appreciable effect of IABP. Miniaturization of the equipment has permitted IABP to be used effectively in pediatric patients.
منابع مشابه
Intestinal cholesterol embolism resulting from intra-aortic balloon pumping: a case report
INTRODUCTION Intra-aortic balloon pumping is used in elective percutaneous coronary intervention for increasing coronary blood flow. However, intra-aortic balloon pumping may decrease visceral blood flow and cause mesenteric ischemia by visceral artery obstruction. CASE PRESENTATION We report the case of a 79-year-old Asian man in whom elective percutaneous coronary intervention was performed...
متن کاملIntra-aortic Balloon Pumping in Patients After Coronary Angioplast
Background. Controversy exists regarding the ability of intra-aortic balloon pumping to increase coronary blood flow in patients with obstructive coronary artery disease. To assess the effects of intra-aortic balloon pumping on coronary hemodynamics, we measured coronary blood flow velocity with a 0.018-in. Doppler-tipped angioplasty guide wire in 15 patients who received an intra-aortic balloo...
متن کاملAugmentation of Coronary Blood Flow by Intra - aortic Balloon Pumping in Patients After Coronary
Background. Controversy exists regarding the ability of intra-aortic balloon pumping to increase coronary blood flow in patients with obstructive coronary artery disease. To assess the effects of intra-aortic balloon pumping on coronary hemodynamics, we measured coronary blood flow velocity with a 0.018-in. Doppler-tipped angioplasty guide wire in 15 patients who received an intra-aortic balloo...
متن کاملAugmentation of Coronary Blood Flow by Intra - aortic Balloon Pumping in Patients After Coronary Angioplast Morton
Background. Controversy exists regarding the ability of intra-aortic balloon pumping to increase coronary blood flow in patients with obstructive coronary artery disease. To assess the effects of intra-aortic balloon pumping on coronary hemodynamics, we measured coronary blood flow velocity with a 0.018-in. Doppler-tipped angioplasty guide wire in 15 patients who received an intra-aortic balloo...
متن کاملAugmentation of Coronary Blood Flow by Intra - aortic Balloon Pumping in Patients After Coronary Angioplast
Background. Controversy exists regarding the ability of intra-aortic balloon pumping to increase coronary blood flow in patients with obstructive coronary artery disease. To assess the effects of intra-aortic balloon pumping on coronary hemodynamics, we measured coronary blood flow velocity with a 0.018-in. Doppler-tipped angioplasty guide wire in 15 patients who received an intra-aortic balloo...