Detecting Physiologically Significant Coronary Arterial Lesions
نویسنده
چکیده
The accuracy of exercise electrocardiography in detecting a physiologically significant coronary artery stenosis has been assessed previously by comparing the exercise test with a coronary arteriogram. The inherent inaccuracy of visually determined percent diameter stenosis measurements might have lead to the conclusion that the exercise electrocardiogram was less accurate than it truly was. To determine the accuracy of the exercise electrocardiography in detecting a physiologically significant coronary stenosis, we studied 40 patients with one-vessel, one-lesion coronary artery disease, a normal resting electrocardiogram, and no hypertrophy or prior infarction. Each patient underwent exercise electrocardiography (Bruce protocol) that was interpreted as abnormal if the ST segment developed 0.1-mV or greater depression 80 msec after the J point. The physiological significance of each coronary stenosis was assessed by measuring of coronary flow reserve (peak divided by resting blood flow velocity) in the stenotic artery using a Doppler catheter and intracoronary papaverine (normal, 3.5 or greater peak/ resting velocity). The percent diameter and percent area stenosis produced by each lesion were determined using quantitative angiography (Brown/Dodge method). Of the 17 patients with reduced coronary flow reserve (3.5 or greater peak/resting blood flow velocity) in the stenotic artery, 14 had an abnormal exercise electrocardiogram (sensitivity, 0.82; 95% confidence interval, 0.70-0.94). Conversely, 20 of 23 patients with normal coronary flow reserves had normal exercise tests (specificity, 0.87; 95% confidence interval, 0.77-0.97). The exercise electrocardiogram was abnormal in each of 11 patients with markedly reduced coronary flow reserve (less than 2.5 peak/resting velocity) and in three of six patients with moderately reduced reserve (2.5-3.4 peak/resting velocity). The products of systolic blood pressure and heart rate at peak exercise were significantly correlated with coronary reserve in patients with truly abnormal exercise tests. In comparison, the sensitivity (0.61; 95% confidence interval, 0.460.76) and specificity (0.73; 95% confidence interval, 0.60-0.86) of exercise electrocardiography in detecting a 60o or greater diameter stenosis may be significantly lower (p <0.05). Exercise electrocardiography, therefore, was a good predictor of the physiological significance (assessed by coronary flow reserve) of a coronary stenosis in patients with a normal resting electrocardiogram and no hypertrophy or prior infarction. Its value in a broader and larger patient population will require further study. These results, however, underscore the importance of a physiological gold standard in assessing the accuracy of noninvasive studies for detecting coronary artery disease. (Circulation 1991;83:412-421)
منابع مشابه
Virtual fractional flow reserve from coronary angiography: modeling the significance of coronary lesions: results from the VIRTU-1 (VIRTUal Fractional Flow Reserve From Coronary Angiography) study.
OBJECTIVES The aim of this study was to develop a computer model that accurately predicts myocardial fractional flow reserve (FFR) from angiographic images alone, in patients with coronary artery disease. BACKGROUND Percutaneous coronary intervention (PCI) guided by FFR is superior to standard assessment alone. FFR-guided PCI results in improved clinical outcomes, a reduction in the number of...
متن کاملCoronary Calcification
THE NEED for methods to detect and measure atherosclerotic lesions in the coronary arteries before the onset of clinical manifestations of coronary heart disease is well recognized by clinicians and epidemiologists.' Since coronary artery lesions are the principal factors in coronary heart disease, they should be more strongly correlated with clinical disease than are the commonly used risk fac...
متن کاملCoronary Calcifications in the Detection of Coronary Artery Disease and Comparison with Electrocardiographic Exercise Testing
Recent studies have noted the limitations of the exercise ECG as a screening test for coronary artery disease (CAD), particularly in asymptomatic patients. To improve the sensitivity and predictive accuracy of noninvasive screening studies, we analyzed the results of using cardiac fluoroscopy (to detect coronary calcifications) in conjunction with electrocardiographic exercise testing to detect...
متن کاملDiagnostic accuracy of seismocardiography compared with electrocardiography for the anatomic and physiologic diagnosis of coronary artery disease during exercise testing.
A multicenter study was performed to compare the diagnostic accuracy of a new technique, seismocardiography, with that of electrocardiography for physiologically and anatomically significant ischemic coronary artery disease (CAD) during exercise stress testing. Five participating centers enrolled 129 patients who had simultaneous seismocardiograms and 12-lead electrocardiograms at the time of t...
متن کاملArterial Stiffness and its Correlation with the Extent of Coronary Artery Disease
Introduction: Coronary artery disease secondary to atherosclerosis is the most common cause of mortality. Coronary angiography is the most precise method for determining the extent of disease in the coronary vascular bed. Arterial stiffness has been proposed as a marker of atherosclerosis in some studies. One of the noninvasive methods for the determination of arterial stiffness is Doppler echo...
متن کامل