Flow-injection chemiluminescence determination of isoniazid using on-line electrogenerated BrO2 as an oxidant

نویسندگان

  • Xingwang Zheng
  • Zhujun Zhang
چکیده

By designing a novel electrolytic flow cell, the strong oxidant BrO2 was electrogenerated on-line in KBr solution and its concentration could be readily adjusted on-line with the flow-injection technique and an electrochemical method. The chemical reaction between BrO2 and luminol in alkaline medium is accompanied by weak emission of light due to chemiluminescence (CL). It was found that the isoniazid can greatly enhance this weak CL intensity when present in the luminol solution. Based on this observation, a new flow-injection CL method for the determination of isoniazid had been proposed in this paper. The detection limit was 7.0 3 1029 g ml21 isoniazid and the CL emission intensity was correlated with the isoniazid concentration in the range 2.0 3 1028–1.0 3 1026 g ml21 with an RSD of < 5% (n = 7). The system was applied successfully to the determination of isoniazid in pharmaceutical preparations and the possible CL mechanism is discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flow-injection electrogenerated chemiluminescence determination of isoniazid using luminol.

Based on a new electrogenerated chemiluminescence (ECL) analytical idea, this paper explains a sensitive and selective flow-injection ECL method using luminol for the determination of isoniazid, based on the sensitizing effect of isoniazid for the weak ECL emission of electrochemically oxidized luminol. Under the optimum experimental conditions, the relative ECL intensity was linear with isonia...

متن کامل

Flow-injection Chemiluminescence Determination of Hydrazine Using On-line Electrogenerated B.rO- as the Oxidant

A novel chemilulninescence flow system for the determination ofhydrazine is presented. It is based on the enhancement effectofhydrazine on the chemiluminescence reaction between IUlninol and BrOin alkaline media. The oxidant BrOwas on-line electrogenerated by constant current electrolysis, resulting in the elimination ofthe inconvenience of its instability. The variables that affect the reactio...

متن کامل

Flow-injection chemiluminescence and electrogenerated chemiluminescence determination of escitalopram oxalate in tablet form.

Rapid, simple and highly sensitive flow-injection (FI) chemiluminescence (CL) and flow-injection electrogenerated chemiluminescence (ECL) methods were developed for the determination of escitalopram oxalate (ESC), a selective serotonin reuptake inhibitor used as an antidepressant drug. The CL method was based on the CL reaction of ESC with acidic cerium(IV) and tris(2,2'-bipyridyl)ruthenium(II)...

متن کامل

Fast determination of thiacloprid by photoinduced chemiluminescence.

A new and sensitive application of chemiluminescence detection has been developed for the determination of the pesticide thiacloprid in water. It was based on the on-line photoreaction of thiacloprid in a basic medium, with quinine acting as the sensitizer of the chemiluminescent response; cerium (IV) in sulfuric acid medium was used as the oxidant. High degrees of automation and reproducibilit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999