Performance evaluation of a multi-pinhole collimator with vertical septa
نویسندگان
چکیده
The authors have previously reported a simulation study on a novel multi-pinhole (MP) collimator that is able to provide improved angular sampling and an enlarged imaging field of view (FOV) when compared to a low-energy high-resolution parallel-hole (LEHR) collimator using a detector of equivalent size. The aim of this study was to develop a miniature single photon emission computerized tomography (SPECT) to verify the performance of the proposed MP collimator with lead vertical septa. A detector with a 70mm 70 mm active area that consisted of a 6 mm-thick NaI(Tl) crystal coupled to a 127 mm-diameter position-sensitive photomultiplier tube (PSPMT) was used. A 7 7 pinhole collimator with a 2 mm-diameter pinhole and a focal length of 40 mm was fabricated to evaluate the performance as compared to a typical LEHR collimator. Additionally, a detector having a 50mm 50 mm active area with 5 5 pinhole and LEHR collimators was investigated to evaluate the enlarged imaging FOV. Planar spatial resolution, sensitivity, and resolution for hotand cold-rod phantom images were acquired. Images were reconstructed using a dedicated maximum likelihood expectation maximization (MLEM) algorithm with an unmatched projector/backprojector pair. The spatial resolution and sensitivity obtained with both collimators were 4.7 mm FWHM and 0.25 cps/mCi at a distance of 60 mm, respectively. Although the detector size was smaller than the phantom, the MP collimator allowed for imaging of the entire phantom while the image obtained with LEHR collimator suffered from a truncation artifact. The reconstructed images, using 60 and 30 projections with both 7 7 pinhole and LEHR collimators, yielded an image of similar quality to that, which was constructed using 120 projections. However, the images reconstructed with 10 projections using a 7 7 pinhole collimator showed better quality than those that used an LEHR collimator. The reconstructed images that used the MP collimator provided high-quality images with an enlarged imaging FOV, even when insufficient angular sampling data were used, which would be of use in the development of a stationary SPECT. & 2011 Elsevier B.V. All rights reserved.
منابع مشابه
Design and implementation of a prototype head and neck phantom for the performance evaluation of gamma imaging systems
BACKGROUND A prototype anthropomorphic head and neck phantom has been designed to simulate the adult head and neck anatomy including some internal organs and tissues of interest, such as thyroid gland and sentinel lymph nodes (SLNs). The design of the head and neck phantom includes an inner jig holding the simulated SLNs and thyroid gland. The thyroid gland structure was manufactured using thre...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملOptimization of Bremsstrahlung imaging in Yttrium internal radiation therapy
Introduction: Treatment efficacy of radiation therapy using Yttrium-90 radionuclide is evaluated by the bremsstrahlung SPECT imaging following radiation therapy. The radioisotopic images have the ability to provide reliable activity map of 90Y distribution. But these images have a low quantitative accuracy in the 90Y bremsstrahlung SPECT imaging, therefore the optimization of...
متن کاملInvestigation of Detector Collimator Effects for Dual Modality Mr -nuclear Imaging
Purpose: Most of the nuclear imaging systems, especially those that are based on single photon emission detection, require the use of a collimatorusually made out of lead (Pb) or some other high Z material such as tungsten (W). Even some PET systems employ some sort of slat-septa collimation, although the important part of PET image formation is done electronically via coincidence detection. Mu...
متن کاملA skew-slit collimator for small-animal SPECT.
UNLABELLED The main objective of this work was the development of a skew-slit collimator for small-animal SPECT to replace the state-of-the-art multipinhole collimator. METHODS A pinhole forms a cone-beam imaging geometry. If the collimator rotates around the object in a circular orbit, the projection measurements acquired by the cone-beam imaging geometry are incomplete and not enough for ar...
متن کامل