A pulsed laser and pulse radiolysis study of amphiphilic chlorophyll derivatives with PDT activity toward malignant melanoma.

نویسندگان

  • L Fiedor
  • A A Gorman
  • I Hamblett
  • V Rosenbach-Belkin
  • Y Salomon
  • A Scherz
  • I Tregub
چکیده

Two amphiphilic derivatives of chlorophyll, which have high potential as photodynamic therapy sensitizers for malignant melanoma have been investigated by a combination of laser flash photolysis and pulse radiolysis. It is shown that direct excitation of monomeric forms of these molecules in both hydrophilic and hydrophobic environments produces significant yields of the corresponding triplet states, which have been characterized in terms of spectral and kinetic parameters. In both environments, scavenging of the triplets by oxygen produces singlet oxygen, O2(1 delta g), with essentially unit efficiency as evidenced by time-resolved IR luminescence measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Laser flash photolysis and pulse radiolysis study on chemical activity of VP-16 and podophyllotoxin

Time-resolved laser flash photolysis and pulse radiolysis have been used to study the chemical activity of podophyllotoxin(PPT) and etoposide(VP-16). The mechanism of photoionization of etoposide and podophyllotoxin has been confirmed and illustrated. It is demonstrated that VP-16 and PPT in aqueous solution can be photoionized at 248 nm to give hydrated electron and neutral radical resulting f...

متن کامل

A Comparative Study Between 595-Nm Pulsed Dye Laser with Cutaneous Compression and Cryotherapy in the Treatment of Solar Lentigines

Background: Although cryotherapy is still the first-line therapy for solar lentigines, due to side effects such as post-inflammatory hyperpigmentation (PIH), especially in patients with darker skin types, pigment specific lasers should be considered as initial treatment. The aim of this study was to evaluate the efficacy and safety of cryotherapy in comparison with 595-nm pulsed dye laser (PDL)...

متن کامل

The LEAF picosecond pulse radiolysis facility at Brookhaven National Laboratory

The BNL Laser-Electron Accelerator Facility (LEAF) uses a laser-pulsed photocathode, radio-frequency electron gun to generate ù7 ps pulses of 8.7 MeV electrons for pulse radiolysis experiments. The compact and operationally simple accelerator system includes synchronized laser pulses that can be used to probe or excite the electron-pulsed samples to examine the dynamics and reactivity of chemic...

متن کامل

Development of a Pulse Radiolysis System by Ultra-fast Super Continuum Probe Light at Waseda University*

We have been studying the pulse radiolysis using photo-cathode rf gun at Waseda Univ. Pulse radiolysis is one of the powerful methods to trace early chemical reactions by ionizing radiation. In pulse radiolysis, the probe light absorption, which produced by active species formed by electron beam of rf gun, is measured at each wavelength and made possible to trace reactions. Therefore, we have u...

متن کامل

Investigation of Effective Parameters on Pulsed Nd:YAG Passive Q-Switched Laser

In this paper, we report the experimental results of a pulsed flash lamped Nd:YAG laser at wavelength of 1064 nm and Qswitched by Cr4+:YAG solid state saturable absorber. We have obtained the output energy (E) and pulse-width ( p τ ) of this laser for various initial transmissions of this saturable absorber. Furthermore, the effect of reflectivity of the output coupler (R), diameter of the rod ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Photochemistry and photobiology

دوره 58 4  شماره 

صفحات  -

تاریخ انتشار 1993