Simultaneous determination of choline and acetylcholine based on a trienzyme chemiluminometric biosensor in a single line flow injection system.

نویسندگان

  • Nobutoshi Kiba
  • Seiji Ito
  • Masaki Tachibana
  • Kazue Tani
  • Hitoshi Koizumi
چکیده

A detector for the simultaneous determination of choline (Ch) and acetylcholine (ACh) based on a sensitive trienzyme chemiluminometric biosensor in a single line flow injection (FI) system is described. Immobilized choline oxidase (ChOx), immobilized peroxidase (POx), immobilized acetylcholinesterase, and coimmobilized ChOx/POx were packed, in turn, in a transparent ETFE tube (1 mm i.d., 75 cm) and the tube was placed in front of a photomultipier tube as a flow cell. Two-peak response was obtained by one injection of the sample solution. The first and second peaks were dependent on the concentrations of Ch and ACh, respectively. The influence of some experimental parameters such as flow rate, amounts of immobilized enzymes on the behavior of the sensor was studied in order to optimize the sensitivity, sample throughput and resolution. Calibration curves were linear at 1 - 1000 nM for Ch and 3 - 3000 nM for ACh. The sample throughput was 25/h without carryover. The FI system was applied to the simultaneous determination of Ch and ACh in rabbit brain tissue homogenates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Trends in biosensor research and development

Trends in biosensor research and development are described. Micromachining techniques have been applied to construct biosensor systems. Several detection units for flow injection analysis have been fabricated. An electrochemical flow cell was fabricated, and both an enzyme immobilized column and an electrochemical detector were integrated. A chemiluminescence detector was also fabricated. Biose...

متن کامل

A Novel Choline Biosensor Based on Immobilization of Enzyme Choline Oxidase on the β-Ga2O3 Nanowires Modified Working Electrode

This article is a report on a novel and high-stability biosensor with minor interference effects of surface modification of working electrode with β-Ga2O3 nanowires (NWs) on choline oxidase biosensor were investigated in an electrochemical detection system. β-Ga2O3 NWs were materialized on the silicon substrate in a catalyst-free growth mechanism. The β-Ga2O<sub...

متن کامل

Flow-injection on-line electrochemical separation/determination of ions using a two-step oil/water-type flow cell system.

A flow system for electrochemical separation and detection of ions was constructed by connecting two oil/water (O/W)-type flow cells, in which a long polarizable O/W interface was formed at the inner surface of a porous poly(tetrafluoroethylene) (PTFE) tube. Using this system, acetylcholine and choline ions, whose ion-transfer potentials are different by only 60 mV, could be separated and deter...

متن کامل

Simultaneous enzymatic/electrochemical determination of glucose and L-glutamine in hybridoma media by flow-injection analysis.

A split-stream flow-injection analysis system is described for simultaneous determination of glucose and L-glutamine in serum-free hybridoma bioprocesses media. Amperometric measurement of glucose is based on anodic oxidation of hydrogen peroxide produced by immobilized glucose oxidase within a triple layer membrane of an integrated flow-through glucose-selective biosensor. Determination of L-g...

متن کامل

Simultaneous determination of D-glucose and 3-hydroxybutyrate by chemiluminescence detection with immobilized enzymes in a flow injection system.

A chemiluminometric flow-through sensor for the simultaneous determination of glucose (Glu) and 3-hydroxybutyrate (HB) in a single sample has been developed. Coimmobilized 3-hydroxybutyrate dehydrogenase/NADH oxidase/peroxidase, a support material, and coimmobilized glucose dehydrogenase/NADH oxidase/peroxidase were packed sequentially in a transparent PTFE tube. The tube was then placed in fro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 19 12  شماره 

صفحات  -

تاریخ انتشار 2003