Test of Relativistic Time Dilation at the ESR

نویسندگان

  • C. Novotny
  • G. Huber
  • S. Karpuk
  • W. Nörtershäuser
  • S. Reinhardt
  • G. Saathoff
  • D. Schwalm
  • A. Wolf
  • F. Bosch
  • C. Geppert
  • H.-J. Kluge
  • T. Kühl
  • M. Steck
چکیده

C. Novotny, G. Huber, S. Karpuk, W. Nörtershäuser, University Mainz, Germany S. Reinhardt, G. Saathoff, D. Schwalm, A. Wolf, MPI for Nuclear Physics, Heidelberg, Germany G. Gwinner, Dept. of Physics and Astronomy, University of Manitoba, Winnipeg, Canada G. Ewald, University Tübingen, Germany F. Bosch, C. Geppert, H.-J. Kluge, T. Kühl, M. Steck, Th. Stöhlker, GSI Darmstadt, Germany T.W.Hänsch, R.Holzwarth, T.Udem, M.Zimmermann, MPI of Quantum Optics, Garching, Germany

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental test of special relativity by laser spectroscopy

The Doppler-free laser-spectroscopic frequency measurement of Doppler-shifted optical lines in forward and backward direction of a fast ion beam permits a sensitive test of the relativistic Doppler-formula and, hence, the relativistic time dilation factor γSR 1⁄4 ð1 ν2 c2 1=2. An experiment on metastable Li, stored at a velocity of v= 0.064c in the Heidelberg heavy-ion storage ring TSR, has con...

متن کامل

Test of time dilation using stored Li+ ions as clocks at relativistic speed.

We present the concluding result from an Ives-Stilwell-type time dilation experiment using 7Li+ ions confined at a velocity of β=v/c=0.338 in the storage ring ESR at Darmstadt. A Λ-type three-level system within the hyperfine structure of the 7Li+3S1 →3P2 line is driven by two laser beams aligned parallel and antiparallel relative to the ion beam. The lasers' Doppler shifted frequencies require...

متن کامل

Aberration of Erythrocyte Sedimentation Rate by Zinc Nanoparticles

Dear Editor, erythrocyte sedimentation rate (ESR) is a useful basic clinical pathology laboratory investigation. It can be helpful in diagnosis and follow-up of several diseases. At present, a new automated method with proven reliability is available for ESR test  (1). Here, the authors report on observation on a laboratory experiment to test the effect of zinc nanoparticles on ESR results. The...

متن کامل

The Relationship Between Reaction Time of Electrical Stapedius Reflex and Auditory Performance in Cochlear-Implanted Children

Background: A common concern in some cochlear-implanted children is the lack of desired progress in auditory and listening skills. Such a concern remains despite proper verbal processor programming, additional disabilities, and continuous participation in hearing rehabilitation programs. A more detailed assessment of pathways and centers of the auditory processing at the lower end of the brain ...

متن کامل

Test of relativistic time dilation with fast optical atomic clocks at different velocities

Time dilation is one of themost fascinating aspects of special relativity as it abolishes the notion of absolute time. It was first observed experimentally by Ives and Stilwell in 1938 using the Doppler effect. Here we report on a method, based on fast optical atomic clocks with large, but different Lorentz boosts, that tests relativistic time dilation with unprecedented precision. The approach...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006