Comparison of the volatile organic compound recovery rates of commercial active samplers for evaluation of indoor air quality in work environments
نویسندگان
چکیده
The Industrial Safety and Health Law in Japan established administrative levels for volatile organic compounds (VOCs) in indoor air. In the present study, these 49 VOCs were extracted from the absorbents of commercial active samplers from Sibata Scientific Technology (carbon-bead active sampler), SKC Inc. (Anasorb CSC sorbent tube), and Gastec (bead-shaped activated carbon tube) using carbon disulfide, and the recovery rates were compared. The VOCs were added to the adsorbents at three concentration levels relative to the administrative levels (×0.5, ×1, and ×2). The following mean recovery rates of the 49 VOCs were obtained at the ×0.5, ×1, and ×2 levels: 86, 93, and 92% for the Sibata sampler; 78, 82, and 84% for the SKC sampler; and 94, 93, and 90% for the Gastec sampler. With the Sibata sampler, the recovery rates of 78% (×0.5), 84% (×1), and 90% (×2) of the VOCs measured in this study were adequate (80-120%); the corresponding percentages for the SKC sampler were 67% (×0.5), 69% (×1), and 69% (×2), and those for the Gastec sampler were 92% (×0.5), 86% (×1), and 86% (×2). The effects of the octanol-water partition coefficients and vapor pressures of the VOCs on the recovery rates were investigated. The recovery rates increased with increases in the octanol-water partition coefficient and the vapor pressure and then leveled off. The recovery rates for the o-, m-, and p-cresol isomers were much lower than those obtained for other VOCs at all three concentration levels and with all samplers.
منابع مشابه
Recent Advances in Microextraction Methods for Sampling and Analysis of Volatile Organic Compounds in Air: A Review
Human exposures to volatile organic compounds (VOCs) are associated with a wide range of health problems. Due to these adverse effects of VOCs on the human health, determination of trace levels of VOCs is very important for accurate assessment of indoor and outdoor exposure. Solid phase microextraction (SPME), needle trap device (NTD) and hollow fiber- liquid phase microextraction (HF-LPME) are...
متن کاملFeasibility study of benzene and toluene removal from air by phytoremediation
Introduction: Phytoremediation is one of the available techniques for removing the volatile organic compound from the air. Benzene and toluene are volatile organic compounds that exist in many occupational environments. Plants are able to reduce benzene and toluene in the air and the use of plants is a simple and consistent solution for the nature to reduce these compositions in the air and imp...
متن کاملDetermining indoor air quality and identifying the origin of odour episodes in indoor environments.
A methodology for identifying volatile organic compounds (VOCs) and determining air quality of indoor air has been developed. The air samples are collected using pump samplers by the inhabitants when they perceive odorous and/or discomfort episodes. Glass multi-sorbent tubes are connected to the pump samplers for the retention of VOC. The analysis is performed by automatic thermal desorption (A...
متن کاملPassive sampling for volatile organic compounds in indoor air-controlled laboratory comparison of four sampler types.
This article describes laboratory testing of four passive diffusive samplers for assessing indoor air concentrations of volatile organic compounds (VOCs), including SKC Ultra II, Radiello®, Waterloo Membrane Sampler (WMS) and Automated Thermal Desorption (ATD) tubes with two different sorbents (Tenax TA and Carbopack B). The testing included 10 VOCs (including chlorinated ethenes, ethanes, and ...
متن کاملEvaluation of air quality in intensive care units and its relationship with sick building syndrome in nurses
Introduction: Indoor air quality can lead to health problems such as Sick Building Syndrome among nurses who spend many hours in intensive care units.The aim of this study was to determine the relationship between Sick Building Syndrome in nurses and indoor air quality of intensive care units in educational hospitals in Rasht. Materials and Methods: This cross-sectional analytical study was pe...
متن کامل