Automated Weaning from Mechanical Ventilation after Off-Pump Coronary Artery Bypass Grafting
نویسندگان
چکیده
BACKGROUND The discontinuation of mechanical ventilation after coronary surgery may prolong and significantly increase the load on intensive care unit personnel. We hypothesized that automated mode using INTELLiVENT-ASV can decrease duration of postoperative mechanical ventilation, reduce workload on medical staff, and provide safe ventilation after off-pump coronary artery bypass grafting (OPCAB). The primary endpoint of our study was to assess the duration of postoperative mechanical ventilation during different modes of weaning from respiratory support (RS) after OPCAB. The secondary endpoint was to assess safety of the automated weaning mode and the number of manual interventions to the ventilator settings during the weaning process in comparison with the protocolized weaning mode. MATERIALS AND METHODS Forty adult patients undergoing elective OPCAB were enrolled into a prospective single-center study. Patients were randomized into two groups: automated weaning (n = 20) using INTELLiVENT-ASV mode with quick-wean option; and protocolized weaning (n = 20), using conventional synchronized intermittent mandatory ventilation (SIMV) + pressure support (PS) mode. We assessed the duration of postoperative ventilation, incidence and duration of unacceptable RS, and the load on medical staff. We also performed the retrospective analysis of 102 patients (standard weaning) who were weaned from ventilator with SIMV + PS mode based on physician's experience without prearranged algorithm. RESULTS AND DISCUSSION Realization of the automated weaning protocol required change in respiratory settings in 2 patients vs. 7 (5-9) adjustments per patient in the protocolized weaning group. Both incidence and duration of unacceptable RS were reduced significantly by means of the automated weaning approach. The FiO2 during spontaneous breathing trials was significantly lower in the automated weaning group: 30 (30-35) vs. 40 (40-45) % in the protocolized weaning group (p < 0.01). The average time until tracheal extubation did not differ in the automated weaning and the protocolized weaning groups: 193 (115-309) and 197 (158-253) min, respectively, but increased to 290 (210-411) min in the standard weaning group. CONCLUSION The automated weaning system after off-pump coronary surgery might provide postoperative ventilation in a more protective way, reduces the workload on medical staff, and does not prolong the duration of weaning from ventilator. The use of automated or protocolized weaning can reduce the duration of postoperative mechanical ventilation in comparison with non-protocolized weaning based on the physician's decision.
منابع مشابه
Avoidance of Dialysis in an End-Stage Renal Disease Patient Status-post Off-pump Coronary Artery Bypass Grafting
Certain benefits are clearly associated with the use of off-pump coronary artery bypass grafting (CABG) as compared with the on-pump CABG. The superiority is more evident in patients with multiple co morbidities including renal failure.We reviewed the medical records of a 67-year-old male with a past medical history that was significant for multiple cardiovascular diseases and new-onset end-sta...
متن کاملPrediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography
Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...
متن کاملThe effect of protocol of weaning from mechanical ventilation on gastrointestinal function in people undergoing coronary artery bypass graft surgery (CABG)
Abstract Aim. The aim of this study was to examine the effect of protocol of weaning from mechanical ventilation on the gastrointestinal function in people undergoing CABG. Background. The most common problems after cardiac surgery in the intensive care unit are change in vital signs, respiratory problems, unsuccessful separation from mechanical ventilation, and gastrointestinal problems. Due t...
متن کاملEffects of positive end-expiratory pressure on mechanical ventilation duration after coronary artery bypass grafting: a randomized clinical trial.
Patients undergoing cardiac surgery remain on mechanical ventilation postoperatively until they regain consciousness. Positive end-expiratory pressure (PEEP) may influence the duration of mechanical ventilation after coronary artery bypass grafting (CABG). The aim of this study was to compare the effects of different levels of PEEP on the duration of mechanical ventilation after coronary artery...
متن کاملEmergency Conversion from Off Pump to Cardiopulmonary Bypass in Patients with Coronary Artery Bypass Graft Surgery
Introduction: As off pump Coronary artery bypass grafting surgery (CABG) is a developing method in coronary cardiac surgery, most surgeons are anxious about the danger of emergency crash conversion. In this observational study we tried to show the rate and outcome of conversion . Material and methods: In this descriptive study about 477 coronary off-pump CABG patients were operated in Ghaem hos...
متن کامل