Variability of relative blood volume during haemodialysis?
نویسنده
چکیده
BACKGROUND A decrease in blood volume is thought to play a role in dialysis-related hypotension. Changes in relative blood volume (RBV) can be assessed by means of continuous haematocrit measurement. We studied the variability of RBV changes, and the relation between RBV and ultrafiltration volume (UV), blood pressure, heart rate, and inferior caval vein (ICV) diameter. METHODS In 10 patients on chronic haemodialysis, RBV measurement was performed during a total of one hundred 4-h haemodialysis sessions. Blood pressure and heart rate were measured at 5-min intervals. ICV diameter was assessed at the start and at the end of dialysis using ultrasonography. RESULTS The changes in RBV showed considerable inter-individual variability. The average change in RBV ranged from -0.5 to -8.2% at 60 min and from -3.7 to -14.5% at 240 min (coefficient of variation (CV) 0.66 and 0.35 respectively). Intra-individual variability was also high (CV at 60 min 0.93; CV at 240 min 0.33). Inter-individual as well as intra-individual variability showed only minor improvement when RBV was corrected for UV. We found a significant correlation between RBV and UV at 60 (r= -0.69; P<0.001) and at 240 min (r= -0.63; P<0.001). There was a significant correlation between RBV and heart rate (r= -0.39; P<0.001), but not between RBV or UV and blood pressure. The level of RBV reduction at which hypotension occurred was also highly variable. ICV diameter decreased from 10.3+/-1.7 mm/m(2) to 7.3+/-1. 5 mm/m(2). There was only a slight, although significant, correlation between ICV diameter and RBV (r= -0.23; P<0.05). The change in ICV-diameter showed a wide variation. CONCLUSIONS RBV changes during haemodialysis showed a considerable intra- and inter-individual variability that could not be explained by differences in UV. No correlation was observed between UV or changes in RBV and either blood pressure or the incidence of hypotension. Heart rate, however, was significantly correlated with RBV. Moreover, IVC diameter was only poorly correlated with RBV, suggesting a redistribution of blood towards the central venous compartment. These data indicate that RBV monitoring is of limited use in the prevention of dialysis-related hypotension, and that the critical level of reduction in RBV at which hypotension occurs depends on cardiovascular defence mechanisms such as sympathetic drive.
منابع مشابه
Bone mineral density in the distal radius and increased risk of fractures in haemodialysis.
variability of relative blood volume during haemodialysis. Nephrol Dial Transplant 2001; 16: 431–432 2. Boer W, Clauss M, Cremaschi L et al. Less intradialytic complications with blood volume control. Nephrol Dial Transplant 2002; 17 [Suppl 1]: 127 3. Kleinoeder T, Cremaschi L, Hickstein H et al. Less complications during hemodialysis by automatic blood volume controlled ultrafiltration. Nephro...
متن کاملAutonomic nervous function during haemodialysis assessed by spectral analysis of heart-rate variability.
1. Short-term autonomic response to haemodialysis-induced hypovolaemia was studied in 30 patients undergoing chronic haemodialysis by analysing power spectra of heart-period variability. Patients were classified as haemodynamically stable (15 patients) and unstable (15 patients) according to their past history of cardiovascular collapse during the treatment. Blood volume, systolic arterial pres...
متن کاملSpecific effect of the infusion of glucose on blood volume during haemodialysis.
BACKGROUND Intradialytic morbid events such as hypotension and cramps during haemodialysis are generally treated by infusion of iso- or hypertonic solutions. However, differences may exist between solutions with respect to plasma refilling and vascular reactivity. METHODS We compared the effect of no infusion (NI) with isovolumetric infusion of isotonic saline 0.9% (IS), saline 3% (HS), isoto...
متن کاملMonitoring of blood volume during haemodialysis treatment of acute renal and multiple organ failures.
The assessment of the level of hydration in the intravascular fluid compartment in acute renal failure (ARF) and multiple organ failure (MOF) is of an utmost importance. However, the data on monitoring of blood volume in these diseases and especially during haemodialysis treatment are lacking. This article summarizing the experience of monitoring of blood volume in chronic haemodialysis suggest...
متن کاملPre-Dialysis Systolic Blood Pressure-Variability Is Independently Associated with All-Cause Mortality in Incident Haemodialysis Patients
Systolic blood pressure variability is an independent risk factor for mortality and cardiovascular events. Standard measures of blood pressure predict outcome poorly in haemodialysis patients. We investigated whether systolic blood pressure variability was associated with mortality in incident haemodialysis patients. We performed a longitudinal observational study of patients commencing haemodi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 15 5 شماره
صفحات -
تاریخ انتشار 2000