RAD Our Experience Using the MobileDaRt Evolution for Neonatal Care

نویسنده

  • Hikaru Umezaki
چکیده

Current advances in neonatal care not only include medical equipment designed for small infants, such as advances in incubators used to maintain infant body temperatures at a constant level and ventilators able to gently control respiration in even the lungs of newborns that weigh less than 1000 grams, but also clearly include major contributions from developments in drugs, such as artificial lung surfactants used to dramatically improve treatment of respiratory distress syndrome, which is the most common disorder facing premature infants with respiratory insufficiency. Because premature infants have insufficiently developed lungs and intestinal tracts, neonatal care primarily involves controlling respiration and providing nutrition via a feeding tube. Consequently, conventional X-rays serve an extremely important role at the NICU (Neonatal Intensive Care Unit), for diagnostics and selection of treatment method. However, as we have gained experience and better understanding of pathophysiology, the use of X-ray imaging has decreased due to concerns regarding radiation exposure. Furthermore, as the use of ultrasound examination equipment has become more widespread, conventional X-rays are no longer used as frequently. It now appears that examinations are mainly performed using ultrasound. Ultrasound examination systems have now become an essential tool in NICUs. That is probably because ultrasound enables immediately viewing still and moving images on-the-spot, which provides more bedside information than a single black and white X-ray image. In addition, treatment with artificial lung surfactants has made respiratory care far easier than before, so there is no longer the need to obtain multiple X-ray images of the lungs. What's more, in the field of neonatal care, it is left up to the neonatal physicians to read X-ray images. With radiography now being treated as an examination method of a previous generation, there are fewer doctors able to read chest and abdominal X-ray images properly. That has no doubt contributed to the decline of conventional radiography. Nevertheless, even with better treatment methods and better medical equipment now available, when faced with an emergency, we are acutely reminded how conventional radiography still is extremely important for imaging. In particular, mobile X-ray systems required time for processing. Therefore, during an emergency, the time delay would make us feel impatient waiting for the images. That is why our hospital introduced a Shimadzu MobileDaRt Evolution unit (Fig. 1) equipped with a compact FPD, which enables obtaining images inside incubators, in our pediatrics department, when the NICU moved to a new building in April 2011. This has also been useful for neonatal care, as described in the cases below.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RAD Exposure Dose to Neonates , Operators and Attendants Using MobileDaRt Evolution

It is well known that chest X-ray imaging plays a very important role in the diagnosis of chest lesions in neonates 1) . However, concerns exist that the exposure of neonatal patients to increasing quantities of radiation through imaging will increase the future risk of cancer development. Additionally, the exposure dose received by the operator and attendants is also of concern, as they often ...

متن کامل

Audit nursing reports in intubated neonates admitted in neonatal intensive care unit of Ayatollah Rouhani Hospital, Babol, Iran

Background: Accurate and complete documentation of nursing records is one of the preconditions of the evidence-based cares and is considered as one of the most important professional tasks in nursing. The aim of the present study was to audit the nursing reports in intubated neonates admitted in neonatal intensive care unit of Ayatollah Rouhani hospital, Babol. Methods: In this cross-section...

متن کامل

Correlation between Quality of Care and Length of Hospital Stay in Neonatal Intensive Care Unit

Background: Length of hospital stay (LHS) is the most important and practical indicator in hospitals, which largely reflects the level of hospital performance and activity. It is also an important indicator for resource planning. Moreover, the quality of care can theoretically be related to LHS. The aim of this study was to investigate the relationship between LHS and quality of nursing care in...

متن کامل

Assessment of the Relationship between Recurrent High-risk Pregnancy and Mothers’ Previous Experience of Having an Infant Admitted to a Neonatal Intensive Care Unit

Background & aim:  High-risk pregnancies increase the risk of Intensive Care Unit (ICU) and Neonatal Intensive Care Unit (NICU) admission in mothers and their newborns. In this study, we aimed to identify the association between the recurrence of high-risk pregnancy and mothers’ previous experience of having an infant admitted to NICU. Methods:We performed a cohort, retrospective study to compa...

متن کامل

Neonatal Thrombosis: Incidence and Risk Factors in a Tertiary Care Hospital in Iran

Background: Neonatal thrombosis is one of the most important challenges among patients admitted in Neonatal Intensive Care Unit (NICU), which can lead to an asymptomatic condition, limb loss or even death. This study was performed to determine the incidence and risk factors of neonatal thrombosis in a tertiary care hospital in Tehran, Iran. Material and Methods: In this historical cohort, all n...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012