The production of radiation tolerant vacuum phototriodes and their HV filters for the Compact Muon Solenoid endcap electromagnetic calorimeter

نویسنده

  • P. R. Hobson
چکیده

Particle detectors which will operate at the Large Hadron Collider face unprecedented challenges in both the number of active detector elements and in operating without maintenance in a high radiation environment for many years. In the Compact Muon Solenoid (CMS) detector the scintillating crystal electromagnetic calorimeter uses vacuum photodetectors in the endcap where the lifetime neutron and hadron fluence is too high for the silicon avalanche photodiodes used in the barrel. Over 15000 radiation tolerant vacuum phototriodes (VPT) have been now been produced by industry for the endcap calorimeter. The VPT have to operate in an environment which has both a significant lifetime dose (up to 50 kGy) from electrons and gamma rays and a high neutron fluence (up to nearly 10 n.cm for E > 100 keV). This paper discusses the steps taken during both the development and production of the VPT to ensure that the response to the scintillation light from the lead tungstate scintillator will not be significantly degraded during the operational lifetime of the experiment. Data from the quality assurance procedures and radiation induced degradation of complete VPT devices is presented. Other components of the endcap calorimeter are also exposed to a similarly intense radiation field. The quality assurance procedure used to select the passive components (resistors and capacitors) used in the high-voltage filter cards is described.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The CMS crystal calorimeter for the LHC

The CMS crystal calorimeter, comprising about 80,000 scintillating lead tungstate crystals read out by avalanche photodiodes (in the barrel) and vacuum phototriodes (in the endcap), is designed to give excellent energy resolution in the demanding LHC environment. It is now entering the construction phase. A status report on the project is presented, including recent results from test beam verif...

متن کامل

Study of the e/pi ratio for the shashlik detector via simulated proton collision events

The intention of this research project was to calculate the e/π ratio for the proposed Shashlik Detector for the Compact Muon Solenoid Experiment by simulating proton collision events in a virtual detector. The e/π ratio is the ratio of the Shashlik’s ability to measure the energy of electromagnetic to hadronic particles. An upgrade is required for the electromagnetic calorimeter due to radiati...

متن کامل

CMS information server CMS NOTE 1999 / 068 The Compact Muon Solenoid Experiment

We investigate the possibility of reducing the data size of the electromagnetic calorimeter(ECAL) of CMS. The Selective Readout is applied first to reduce the data size at a manageable level. Then various data compression methods are considered, and their performances are estimated using the data from the full simulation of the ECAL system. A reduction of the average event size by a factor of t...

متن کامل

Study of the Optimum Momentum Resolution in the CMS Muon System

This project deals with the development of equations from simulation data to assign momentum to muons moving through the endcap region of the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider at The European Center for Nuclear Research. The layout of the CMS experiment, the endcap detector operation, and the details of developing momentum-assignment equations are described. A ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007