Detection of Platelet Clumps on Peripheral Blood Smears by CellaVision DM96 System and Microscopic Review.

نویسندگان

  • Gene Gulati
  • Guldeep Uppal
  • Alina Dulau Florea
  • Jerald Gong
چکیده

OBJECTIVE To determine and optimize the sensitivity of the CellaVision DM96 automated image-analysis system in detecting platelet (PLT) clumps on blood smears and to assess the reliability of the traditional laboratory practice of examining only the feather edge of the smear for PLT clumps. METHODS We processed 102 blood smears that revealed PLT clumps on microscopic review, using the CellaVision DM96, and reviewed the results for the ability of the analyzer to detect these clumps. We obtained the data regarding relative distribution of PLT clumps on different parts of the blood smear (feather edge, lateral edges, and readable area) from our microscopic-review observations. RESULTS The sensitivity of the Cellavision DM96 in detecting PLT clumps was between 40.4% and 82.8%, depending on the number of screens reviewed for this variable. Via microscopic review of the smears, the PLT-clump detection rate increased from 85.3%, obtained by examining only the feather edge, to 99.0%, obtained by examining the feather edge plus the readable area. CONCLUSION The sensitivity of the DM96 for detecting PLT clumps can be maximized to 82.8% by reviewing the entire white blood cell screen and the entire PLT screen. Microscopic review of the blood smears yielded a PLT-clump detection rate of 99.0% when we examined the feather edge and the readable area of the smear.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance evaluation and relevance of the CellaVision™ DM96 system in routine analysis and in patients with malignant hematological diseases

The CellaVisiontrade mark DM96 is an automated image analysis system dedicated to locating and preclassifying the various types of white blood cells in peripheral blood smears. The system also partially characterizes of the red blood cell morphology and is able to perform platelet counts. We routinely analyzed the blood samples from 440 patients with quantitative and/or qualitative abnormalitie...

متن کامل

[Automated cell recognition in hematology: CellaVision DM96 TM system].

Cellular morphology has a predominant place in diagnosis of hematological malignancies in spite of flow cytometry, cytogenetic and molecular biology progresses. CellaVisionDM8/96TM is automated microscope and image analysis software which are able to characterize white and red blood cells morphology and to perform platelets counts in peripheral blood smears. Validity of results is always submit...

متن کامل

Can automated blood film analysis replace the manual differential? An evaluation of the CellaVision DM96 automated image analysis system.

Automation of differentials is desirable for economic and time-saving reasons. Over the last 20 years, automated imaging processes have started to be introduced where stained blood films are scanned by a computer-driven microscope and leucocytes classified; however, early methods were slow and had difficulty in classifying abnormal cells. More recently the CellaVision DM96 (CellaVision AB, Lund...

متن کامل

Evaluation of the accuracy of the CellaVision™ DM96 in a high HIV-prevalence population in South Africa

INTRODUCTION The CellaVision™ DM96 (DM96) is a digital microscopy system which performs well in developed countries. However, to date it has not been evaluated in Africa, where the pathology spectrum encountered is very different. In particular, its utility in a setting with high HIV prevalence has not been assessed, which is of interest because of the morphological aberrations often seen in HI...

متن کامل

Detection of Plasmodium Vivax by Nested PCR in marious areas of western north of Iran

Introduction: Malaria is one of the most important parasitic diseases in tropical and sub-tropical areas of the world and kills a large number of People annually. Diagnosis of the disease is preformed by microscopic and molecular methods. This study has been designed for detecting of latent/sub-patent infection caused by plasmodium vivax in individuals with history of vivax malaria without an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Laboratory medicine

دوره 45 4  شماره 

صفحات  -

تاریخ انتشار 2014