"Body-In-The-Loop": Optimizing Device Parameters Using Measures of Instantaneous Energetic Cost

نویسندگان

  • Wyatt Felt
  • Jessica C. Selinger
  • J. Maxwell Donelan
  • C. David Remy
  • Yongtang Shi
چکیده

This paper demonstrates methods for the online optimization of assistive robotic devices such as powered prostheses, orthoses and exoskeletons. Our algorithms estimate the value of a physiological objective in real-time (with a body "in-the-loop") and use this information to identify optimal device parameters. To handle sensor data that are noisy and dynamically delayed, we rely on a combination of dynamic estimation and response surface identification. We evaluated three algorithms (Steady-State Cost Mapping, Instantaneous Cost Mapping, and Instantaneous Cost Gradient Search) with eight healthy human subjects. Steady-State Cost Mapping is an established technique that fits a cubic polynomial to averages of steady-state measures at different parameter settings. The optimal parameter value is determined from the polynomial fit. Using a continuous sweep over a range of parameters and taking into account measurement dynamics, Instantaneous Cost Mapping identifies a cubic polynomial more quickly. Instantaneous Cost Gradient Search uses a similar technique to iteratively approach the optimal parameter value using estimates of the local gradient. To evaluate these methods in a simple and repeatable way, we prescribed step frequency via a metronome and optimized this frequency to minimize metabolic energetic cost. This use of step frequency allows a comparison of our results to established techniques and enables others to replicate our methods. Our results show that all three methods achieve similar accuracy in estimating optimal step frequency. For all methods, the average error between the predicted minima and the subjects' preferred step frequencies was less than 1% with a standard deviation between 4% and 5%. Using Instantaneous Cost Mapping, we were able to reduce subject walking-time from over an hour to less than 10 minutes. While, for a single parameter, the Instantaneous Cost Gradient Search is not much faster than Steady-State Cost Mapping, the Instantaneous Cost Gradient Search extends favorably to multi-dimensional parameter spaces.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Estimating instantaneous energetic cost during non-steady-state gait.

Respiratory measures of oxygen and carbon dioxide are routinely used to estimate the body's steady-state metabolic energy use. However, slow mitochondrial dynamics, long transit times, complex respiratory control mechanisms, and high breath-by-breath variability obscure the relationship between the body's instantaneous energy demands (instantaneous energetic cost) and that measured from respira...

متن کامل

Influence of Uncertainty in Metabolic Dynamic Time Constant on Instantaneous Cost Mapping Techniques

Introduction Newly developed ‘body-in-the-loop’ optimization algorithms have the potential to dramatically improve the performance of robotic assistive devices, such as prostheses and exoskeletons. These algorithms minimize a physiological cost function (e.g., energy expenditure) over a range of parameter values (e.g., controller timing) to determine the optimal parameter setting [1]. Successfu...

متن کامل

A comparative study of two meta-heuristic algorithms in optimizing cost of reinforced concrete segmental lining

In this work, we tried to automatically optimize the cost of the concrete segmental lining used as a support system in the case study of Mashhad Urban Railway Line 2 located in NE Iran. Two meta-heuristic optimization methods including particle swarm optimization (PSO) and imperialist competitive algorithm (ICA) were presented. The penalty function was used for unfeasible solutions, and the seg...

متن کامل

Energetic Cost of Runnning Stability Evaluated with Wireless Trunk Accelerometry

The purpose of this study was to determine inter-individual variance in the energetic cost of running (Ec) using dynamic stability measures derived from a single tri-axial trunk accelerometer. These measures were extracted from fifteen male recreational runners at their fastest steady-state treadmill running speed. A select group of dynamic stability measures were entered in a hierarchical regr...

متن کامل

A New Strategy for Simultaneous Compensation of Instantaneous Reactive Power and Harmonics of Non-Linear Loads (RESEARCH NOTE)

This paper presents a new control method for simultaneous compensation of instantaneous reactive power and current harmonics by parallel active filters (PAFs). Reference compensating currents of PAF are calculated using the subtraction of instantaneous power from its average value. In this way, it is possible omitting high/low pass filter(s) from the control circuit of PAF, which usually result...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015