Bone cutting capacity and osseointegration of surface-treated orthodontic mini-implants
نویسندگان
چکیده
OBJECTIVE The objective of the study was to evaluate the practicality and the validity of different surface treatments of self-drilling orthodontic mini-implants (OMIs) by comparing bone cutting capacity and osseointegration. METHODS Self-drilling OMIs were surface-treated in three ways: Acid etched (Etched), resorbable blasting media (RBM), partially resorbabla balsting media (Hybrid). We compared the bone cutting capacity by measuring insertion depths into artificial bone (polyurethane foam). To compare osseointegration, OMIs were placed in the tibia of 25 rabbits and the removal torque value was measured at 1, 2, 4, and 8 weeks after placement. The specimens were analyzed by optical microscopy, scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). RESULTS The bone cutting capacity of the etched and hybrid group was lower than the machined (control) group, and was most inhibited in the RBM group (p < 0.05). At 4 weeks, the removal torque in the machined group was significantly decreased (p < 0.05), but was increased in the etched group (p < 0.05). In the hybrid group, the removal torque significantly increased at 2 weeks, and was the highest among all measured values at 8 weeks (p < 0.05). The infiltration of bone-like tissue surface was evaluated by SEM, and calcium and phosphorus were detected via EDS only in the hybrid group. CONCLUSIONS Partial RBM surface treatment (hybrid type in this study) produced the most stable self-drilling OMIs, without a corresponding reduction in bone cutting capacity.
منابع مشابه
Evaluation of Stability of Surface-Treated Mini-Implants in Diabetic Rabbits
Introduction. The purpose of this study was to investigate effects of surface treatment of mini-implants in diabetes-induced rabbits by comparing osseointegration around mini-implants. Methods. Twelve New Zealand white rabbits were divided into two groups (alloxan-induced diabetic group and control group). A total of 48 mini-implants were placed after four weeks of diabetic induction. 24 mini-i...
متن کاملRotational resistance of surface-treated mini-implants.
OBJECTIVE To test the hypothesis that there is no difference in the stability and resistance to rotational moments of early loaded sandblasted and acid-etched (SLA) mini-implants and those of machined-surface implants of the same size and shape. MATERIALS AND METHODS A randomized complete block design was used in 12 skeletally mature male beagle dogs. Ninety-six orthodontic mini-implants were...
متن کاملReader's Forum
A1. The temporary skeletal anchorage device used in this study, C-implant, requires higher removal torque compared to other orthodontic mini-implants because of its greater osseointegration potential. It also means that the C-implant allows application of multi-directional force system such as retraction combined with intrusion by concurrent use of intraand intermaxillary elastics. In such case...
متن کاملThe Effect Of Restoration Type On Osseointegration of Dental Implants: A Histological Analysis In Dogs
Background and Objective: The concept of immediate occlusal loading with dental implants offers several advantages. In this research, the effect of type of restoration on Osseointegration rate of dental implants was histologically evaluated. Materials and Methods: Three months prior to implantation, the lower premolar teeth of 15 dogs were extracted. Then, 3 to 4 Maestro™ implants were plac...
متن کاملرفتار سلول استخوان ساز MG-63 بر روی سطح تیتانیم اصلاح شده با محلول اسیدی
The osseointegration of oral implants is related to the early interactions between osteoblastic cells and titanium surface. Chemical surface modification of titanium (Ti) implants is used to improve peri-implant bone growth, bone-to-implant contact, and adhesion strength. Thus, in this study, the surface topography, chemistry, and biocompatibility of polished titanium surface treated with mixe...
متن کامل