Real-time measurement of fibers using an HY-differential mobility analyzer with an optical particle counter (KOFAM)

نویسندگان

  • Sungwon Choi
  • Kwangmyung Jang
  • Kyunghoon Park
  • Hyunwook Kim
چکیده

This study investigated the applicability of an HY-differential mobility analyzer with an optical particle counter (HY-DMA/OPC), named as KOFAM, for counting fibrous matters in real time. Fibers separated from particles by the HY-DMA were counted with an OPC. To assess the KOFAM performance, the proposed method and the conventional gold standard phase contrast microscopy (PCM) method were compared in terms of variables such as recovery, relative difference, coefficient of determination, and conformity. The optimal sheath-to-aerosol (outlet) flow ratio of the internal flow in the HY-DMA was determined to be 1.6:1. In terms of recovery of the HY-DMA, the highest recovery was obtained at a voltage of 500 V regardless of which type of asbestos was tested. The recovery rate for serpentine was 45.5% and that for amphibole was 34.9%. The coefficients of determination of serpentine (R2 = 0.89) and amphibole (R2 = 0.87) were highly correlated. With respect to the coefficient of variation (CV), the KOFAM demonstrated superior performance over the M7400AD and F-1 methods and showed almost no difference from the PCM method (KOFAM: 22.5%, M7400AD: 32.4%, F-1: 88.8%, and PCM: 21.9%). There was no statistically significant difference between concentration measurements of the KOFAM and PCM analyses. Accordingly, it was concluded that the KOFAM can be used as a superior alternative to conventional fiber measurement methods. The preliminary results support the use of the KOFAM for constant measurement of airborne asbestos concentrations in real time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Direct Study of the Particle Differential Mobility Analyzer (DMA) Systems: a review article

Background & Aim: One of the unknown equipment inside our country, especially for researchers, is the DMA system, which used to particle size distribution, especially for nanoparticles. The purpose of this paper was to review the studies carried out in this field, assessment of the evolution and importance of the application of this system and introduce the true position of this system among re...

متن کامل

Determination of Aerosol Particle Size Distribution using Electrical Differential Mobility Analyzer (DMA)

Introduction: Determining the size distribution of the particles for assessing their effects on human health and their control mechanisms is very effective. One of the most important equipment used in determining particle size distribution is the DMA. In this study, in addition to the design and construction of a DMA, the size distribution measurement of aerosol particles was carried out. Mate...

متن کامل

Electrical Mobility Spectrometer Using a Diethylene Glycol Condensation Particle Counter for Measurement of Aerosol Size Distributions Down to 1 nm

We report a new scanning mobility particle spectrometer (SMPS) for measuring number size distributions of particles down to ∼1 nm mobility diameter. This SMPS includes an aerosol charger, a TSI 3085 nano differential mobility analyzer (nanoDMA), an ultrafine condensation particle counter (UCPC) using diethylene glycol (DEG) as the working fluid, and a conventional butanol CPC (the “booster”) to...

متن کامل

Design and Construction of an Aerosol Particle Classification System Based on Electrical Mobility

Introduction: The application of particles’ electrical mobility in the electric field has always been an important concern, as the functional basis of a number of particle measuring and classification instrumentations. The objective of this study was to design and construct an aerosol particles classification system using electrical mobility feature in laboratory scale. Methodology: This labo...

متن کامل

Observations of smoke-influenced aerosol during the Yosemite Aerosol Characterization Study: Size distributions and chemical composition

[1] The Yosemite Aerosol Characterization Study (YACS) took place in Yosemite National Park from 15 July to 5 September 2002, during which time air masses arriving at the site were believed to have been influenced by smoke from numerous wildfires active in the western United States. Physical, optical, and chemical aerosol measurements were made to characterize visibility and to help define aero...

متن کامل