Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates

نویسندگان

  • Paritosh Gogna
  • Harpal Singh Selhi
  • Rohit Singla
  • Ashish Devgan
  • Narender Kumar Magu
  • Pankaj Mahindra
  • Mohammad Yamin
چکیده

Background. Dorsally comminuted distal radius fractures are unstable fractures and represent a treatment challenge. The objective of this study was to evaluate the functional and radiological outcome of dorsally comminuted fractures of the distal radius fixed with a volar locking plate. Patients and Methods. Thirty-three consecutive patients with dorsally comminuted fractures of the distal end of the radius were treated by open reduction and internal fixation with AO 2.4 mm (n = 19)/3.5 mm (n = 14) volar locking distal radius plate (Synthes, Switzerland, marketed by Synthes India Pvt. Ltd.). There were 7 type A3, 8 type C2, and 18 type C3 fractures. The patients were followed up at 6 weeks, 3 months, 6 months, and 1 year postoperatively. Subjective assessment was done as per Disabilities Arm, Shoulder, and Hand (DASH) questionnaire. Functional evaluation was done by measuring grip strength and range of motion around the wrist; the radiological determinants were radial angle, radial length, volar angle, and ulnar variance. The final assessment was done as per Demerit point system of Saito. Results. There were 23 males and 10 females with an average age of 44.12 ± 18.63 years (18-61 years). Clinicoradiological consolidation of the fracture was observed in all cases at a mean of 9.6 weeks (range 7-12 weeks). The average final extension was 58.15° ± 7.83°, flexion was 54.62° ± 11.23°, supination was 84.23° ± 6.02°, and pronation was 80.92° ± 5.54°. Demerit point system of Saito yielded excellent results in 79% (n = 26), good in 18% (n = 6), and fair in 3% (n = 1) patients. Three patients had loss of reduction but none of the patients had tendon irritation or ruptures, implant failure, or nonunion at the end of an one-year followup. Conclusion. Volar locking plate fixation for dorsally comminuted distal radius fractures results in good to excellent functional outcomes despite a high incidence of loss of reduction and fracture collapse.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomy of the distal volar radius and its implications on volar plate osteosynthesis

Volar plate fixation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted distal radial fractures. When doing volar plating of radius fractures, we observed a considerable variation in the morphology of the distal radius. Research in the literature reveals rare information about the anatomic variatio...

متن کامل

Various volar shapes of the distal radius and its implications on volar plate osteosynthesis

Volar plate fi xation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted distal radial fractures. When doing volar plating of radius fractures, we observed a considerable variation in the morphology of the distal radius. Research in the literature reveals rare information about the anatomic variati...

متن کامل

Internal fixation of dorsally displaced fractures of the distal part of the radius. A biomechanical analysis of volar plate fracture stability.

BACKGROUND Volar plate fixation with use of either a locking plate or a neutralization plate has become increasingly popular among surgeons for the treatment of dorsally comminuted extra-articular distal radial fractures. The purpose of the present study was to compare the relative stability of five distal radial plates (four volar and one dorsal), all of which are commonly used for the treatme...

متن کامل

Volar plate fixation of distal radius fractures.

Volar fixed angle fixation may be considered as the beginning of a new era in restoring wrist function to patients with dorsally displaced distal radius fractures even in the face of comminuted or osteopenic bone. A thorough understanding of the anatomy of the wrist is a prerequisite when volarly approaching dorsally displaced distal radius fractures. The demonstration of the device theoretical...

متن کامل

Distal radius measurements and efficacy of fixed-angle locking volar plates.

AIM For surgical treatment of unstable distal radius fractures, fixed-angled locking volar plate fixation is becoming popular nowadays because of some advantages over other surgical techniques. In this article, we discuss the fitting of fixed-angle locking volar plates to the distal radius in relation to the changes in the distal radial angles. MATERIALS AND METHODS First, we took conventiona...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2013  شماره 

صفحات  -

تاریخ انتشار 2013