Shielding effect of a customized intraoral mold including lead material in high-dose-rate 192-Ir brachytherapy for oral cavity cancer.
نویسندگان
چکیده
A high-dose-rate (HDR) 192-Ir brachytherapy using a customized intraoral mold is effective for superficial oral cavity cancer, and the surrounding normal tissue is kept away from the radioactive source with gauze pads and/or mouth piece for reducing the dose on the normal tissues. In the Tokushima university hospital, the mold has a lead shield which utilizes the space prepared with sufficient border-molding by a specific dental technique using modeling compound. In HDR 192-Ir brachytherapy using a lead shielded customized intraoral mold, there are no reports measuring the absorbed dose. The purpose of the present study is to measure the absorbed dose and discuss the optimum thickness of lead in HDR 192-Ir brachytherapy using a customized intraoral mold with lead shield using a 1 cm thickness mimic mold. The thickness of lead in the mold could be changed by varying the arrangement of 0.1 cm thickness sheet of the acrylic resin plate and lead. The measured doses at the lateral surface of the mold with thermo-luminescence dosimeter were reduced to 1.12, 0.79, 0.57, 0.41, 0.31, 0.24 and 0.19 Gy and the ratios to the prescription dose were reduced to 56, 40, 29, 21, 16, 12 and 10 percent as lead thickness increased from 0 to 0.6 cm in 0.1 cm increments, respectively. A 0.3 cm thickness lead was considered to be required for a 1 cm thickness mold, and it was necessary to thicken the lead as much as possible with the constraint of limited space in the oral cavity, especially at the fornix vestibule.
منابع مشابه
Calculating of Dose Distribution in Tongue Brachytherapy by Different Radioisotopes using Monte Carlo Simulation and Comparing by Experimental Data
Introduction: Among different kinds of oral cavity cancers, the frequency of tongue cancer occurrence is more significant. Brachytherapy is the most common method to cure tongue cancers. Long sources are used in different techniques of tongue brachytherapy. The objective of this study is to asses the dose distribution around long sources, comparing different radioisotopes as brachytherapy sourc...
متن کاملVerification of delivered dose to the Lips carcinoma tumors with HDR brachytherapy sources: 192Ir and 60CO in an exclusive plexiglass Phantom.
Introduction: Brachytherapy, especially using manually after loaded Iridium-192 and Cobalt-60, can be applied as a sole treatment, as a treatment complementary to surgery, and as a local boost in combination with EBRT. The use of HDR brachytherapy catheters incorporated in removable dental molds allows repeated, highly reproducible, fractionated outpatient brachytherapy of supe...
متن کاملEvaluate Shielding Design of the Brachytherapy Unit by Using Monte Carlo Simulation Code
Shielding design is necessary for brachytherapy treatment room in order to protect the general public and employees. The main objective of this study was to investigate whether the protective unit of our Brachytherapy Centre provided adequate protection to the health and safety assessment of radiobiological impact. In this study, we estimated the effect of radiobiological protection from a sing...
متن کاملApplicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
متن کاملNew era of electronic brachytherapy
Traditional brachytherapy refers to the placement of radioactive sources on or inside the cancer tissues. Based on the type of sources, brachytherapy can be classified as radionuclide and electronic brachytherapy. Electronic brachytherapy uses miniaturized X-ray sources instead of radionuclides to deliver high doses of radiation. The advantages of electronic brachytherapy include low dose to or...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of radiation research
دوره 53 1 شماره
صفحات -
تاریخ انتشار 2012