Short-circuit analysis of the onsite electric power system at Ringhals unit 4 Master of Science Thesis in the Master Degree Programme Electric Power Engineering

نویسنده

  • MIKAEL NILSSON
چکیده

Because of an upcoming modernization of the electric system in unit 3 and 4 at Ringhals AB, new short-circuit current calculations have to be made. This report focuses on the development of a model of the electric power system in a nuclear power plant in order to perform short-circuit current calculations. In this model, different components can be exchanged in order to investigate future adjustments in the system. The IEC 60909-0 standard is used in order to calculate various types of short-circuit currents for the power system. The usage of the standard IEC 60909-0 is in some cases quite conservative, which is positive when calculating currents for a system of this type. For the standard IEC 60909-0, some correction factors are introduced. The factor KT is used for correction of the impedance of the transformers and KG is used for the correction of the generator impedance. For the voltage, two factors are introduced to increase/decrease the voltage at the fault location. The power system is divided into several different voltage levels, where calculations are made for short circuits on the 6,6 kV and 500 V levels. Nine different cases are set up in order to evaluate the system, so that the maximum and minimum currents can be determined. The different currents examined appear when a balanced three-phase fault occurs. The calculated currents are the maximum initial short-circuit current, the peak short-circuit current, and the maximum and minimum steady-state short-circuit currents. Among the cases that have been examined, the real case that gives the highest maximum initial current is case 3 for all buses. In the same case, the highest peak current and maximum steady-state current appear. The lowest minimum steady-state current is found in case 8 for the buses H4x-y6 and VHC4x, and in case 9 for the buses D4x-y6 and DHC4x. In the performed sensitivity analysis, the new calculations have been compared to previous results. The deviations are small for all cases, which means that the new calculations have been performed with great satisfaction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability Based Optimal Preventive Maintenance Policy for High Voltage Circuit Breakers in Power Plants

  Electric power industry have always try to provide reliable electricity to customers and at the same time decrease system costs. High Voltage circuit-breakers are an essential part of the power network. This study has developed a maintenance and replacement scheduling model for high voltage circuit- breakers that minimize maintenance costs while maintaining the acceptable reliability. This mo...

متن کامل

Congestion Management: Re-dispatch and Application of FACTS Master of Science Thesis in the International Master Degree Programme, Electric Power Engineering

............................................................................................................................. iv Acknowledgements ............................................................................................................. v

متن کامل

Electric Differential for an Electric Vehicle with Four Independent Driven Motors and Four Wheels Steering Ability Using Improved Fictitious Master Synchronization Strategy

Using an Electric Differential (ED) in electric vehicle has many advantages such as flexibility and direct torque control of the wheels during cornering and risky maneuvers. Despite its reported successes and advantages, the ED has several problems limits its applicability, for instance, an increment of control loops and an increase of computational effort. In this paper, an electric differenti...

متن کامل

Failure Mode and Effect Analysis Power Plant Boiler

The current electricity demand is increasing, and now the government has involved third parties in the implementation of electricity so that investors compete in building infrastructure in order to apply electricity. Thermal power is one source that has a fast break event point compared to other resources that more interested investors even with all forms of pollution caused. A form of heat pow...

متن کامل

Implications of the Dichotomy of Modal Participation Factors for Monitoring and Control of Electric Power Networks

Title of thesis: IMPLICATIONS OF THE DICHOTOMY OF MODAL PARTICIPATION FACTORS FOR MONITORING AND CONTROL OF ELECTRIC POWER NETWORKS Paul Kenton Tschirhart, Master of Science, 2013 Thesis directed by: Professor Eyad Abed Department of Electrical Engineering Steadily increasing demand for electricity has led to today’s electric power networks often being stressed to their stability limits. Improv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010