Measurement of serum magnesium with a centrifugal analyzer.
نویسندگان
چکیده
We show how serum magnesium can be determined with a centrifugal analyzer. The method is based upon a manual procedure involving magnesium/calmagite complex formation in an alkaline reagent mixture. The assay, performed at 30 degrees C, requires 5 mul of serum in a final reaction volume of 405 mul, including 350 mul of reagent mixture. The stable color produced at 1 min is measured at 520 nm. Linearity studies showed that Beer's law was followed to 50 mg/liter. Average analytical recovery was 97.3%. Within-day studies showed CV's of 3.36% and 1.09%, compared to day-to-day variations of 5.32% and 3.04% at 18.8 and 46.6 mg of magnesium per liter, respectively. Correlation studies with the manual method, the Du Pont aca (methylthymol blue compleximetric) procedure, and atomic absorption spectroscopy showed correlation coefficients of 0.996, 0.976, and 0.950, respectively. Results compare excellently with those by common present methods. The method is fast, economical, reliable, and applicable to small specimen volumes.
منابع مشابه
Use of a Laser-equipped Centrifugal Analyzer for Kinetic Measurement of Serum lgG
Use of a visible laser in an Aminco “Rotochem” centrifugal analyzer enables light-scattering measurements to be made with this instrument. The modification is technically simple, inexpensive, and requires no fundamental changes in basic instrument design. The laser-modified analyzer has been applied to the measurement of lgG in serum. A two-point kinetic analysis is used to quantitate lgG from ...
متن کاملImproved method for measurement of inorganic phosphate in serum with a centrifugal analyzer.
A direct mehtod [Clin. Chim. Acta 46, 113 (1973)] for determination of inorganic phosphate in serum was adapted for use with a centrifugal analyzer. Contamination is minimized and analysis rate maximized by doing the reaction in the reagent wells of the transfer disc and by utilizing the high-speed spectrophotometric and data-reduction capabilities of the centrifugal analyzer. Hemolysis, icteru...
متن کاملAutomated calmagite compleximetric measurement of magnesium in serum, with sequential addition of EDTA to eliminate endogenous interference.
We describe an automated method for magnesium assay, for use with the Cobas-Bio centrifugal analyzer. Magnesium is reacted with calmagite, a dye, and the absorbance of the magnesium-dye complex at 520 nm is measured. EDTA is then added to break up the complex and the absorbance at 520 nm is re-measured to correct for sample color and turbidity. Including ethylene glycol bis(beta-aminoethyl ethe...
متن کاملMeasurement of total protein and albumin in serum with a centrifugal analyzer.
In most clinical chemistry laboratories, mechanized procedures are essential for measurement of serum total protein and albumin. The biuret reaction is well established as the most practical approach to mechanized total protein measurements (1-4); albumin has posed a more difficult problem, with several procedures being proposed, some of which have involved salt fractionation (1-4), electrophor...
متن کاملStudies on measurement of plasma magnesium: application of the Magon dye method to the "Monarch" centrifugal analyzer.
The "Magnesium Liquid Stable Reagent Set" from Medical Analysis Systems, Inc., is evaluated. The method, which involves Magon dye binding and bichromatic absorbance measurements, was used in a Monarch centrifugal analyzer. Results were compared with those by atomic absorption spectrometry. The calibration curve for the Magon method is linear to 2.5 mmol/L, with a 2-microL sample volume. Analyti...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 23 2 PT. 1 شماره
صفحات -
تاریخ انتشار 1977