Homogeneous immunofluorometric assays of alpha-fetoprotein with macroporous, monosized particles and flow cytometry.

نویسندگان

  • J Frengen
  • R Schmid
  • B Kierulf
  • K Nustad
  • E Paus
  • A Berge
  • T Lindmo
چکیده

We evaluated two homogeneous immunofluorometric assays (IFMAs) of alpha-fetoprotein (AFP) based on new macroporous acrylate particles combined with flow cytometry. The standard IFMA, requiring 1 h of incubation, provided a working range from 1.8 to > 900 kIU/L (CV < 10%) and a detection limit of 0.6 kIU/L. Use of overnight incubation and a lower particle concentration extended the working range by 1 decade in the lower end. Analytical recoveries for the standard IFMA varied between 97% and 108%. The slope and y-intercept of the regression line correlating measurements by the standard IFMA and a routine immunoradiometric assay were not significantly different from 1 and 0, respectively (P > 0.5), and the correlation coefficient was 0.996. High precision and warning of spuriously high measurements were obtained by including in each sample separate particle types for detecting instrument instability and measuring nonspecific binding only.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New screening system for simultaneous determination of two marker proteins by homogeneous enzyme immunoassay.

AIMS To save time and labour in mass screening, by detecting two marker proteins on one specimen using only one test. METHODS alpha Fetoprotein and ferritin were chosen to demonstrate the principal of this system. The assay reagents were horseradish peroxidase (HRP)-labelled anti-alpha fetoprotein and HRP-labelled anti-ferritin antibodies. After the serum sample had been incubated with these ...

متن کامل

Experimental Investigation of the Permeability and Inertial Effect on Fluid Flow through Homogeneous Porous Media

The value of the permeability in fluid flow through porous media is important for process investigation. In low Reynolds number, the classic Darcy’s law is suitable for simulation of fluid flow. In this paper, an experimental study for evaluation of preformed fiber permeability has been done. Also, the deviations from the classical Darcy law by experimental and numerical simulation of the N...

متن کامل

MONOCLONAL ANTIBODIES TO HUMAN ALPHA-FETOPROTEIN

Alpha-fetoprotein (AFP), a serum glycoprotein belonging to the onco-developmental proteins group, serves as a marker both in cancer research and in studies concerning fetal development and fetal pathophysiology. Monoclonal anti-AFP antibodies are essential reagents in developing appropriate techniques for measurement of this protein. In this study, in order to produce anti-AFP monoclonal a...

متن کامل

Analyte and label binding assay read by flow cytometry.

A new immunometric two-site sandwich assay is introduced, in which a label-scavenging binding partner is added to the sample in addition to the analyte-binding partner. The scavenger binding partner binds excess label antibody, giving a signal proportional to the amount of excess label antibody in the sample solution. A set of two calibration curves is obtained from the two binding partners sim...

متن کامل

Evaluating Commercial Macroporous Resin (D201) for Uranium Uptake in Static and Dynamic Fixed Bed Ion Exchange Column

As part of the development of equipment and innovative technology for the process flow-sheet, a study on the selection of good resin for uranium uptake is ongoing. Both static and dynamic column equilibrium testing upon synthetic and Gattar pregnant leach solutions (PLS) were carried out to estimate the change of total capacity and breakthrough capacity of the commercial macroporous anion excha...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 39 10  شماره 

صفحات  -

تاریخ انتشار 1993