An analysis of observer‐rated functional vision in patients implanted with the Argus II Retinal Prosthesis System at three years

نویسندگان

  • Duane R Geruschat
  • Thomas P Richards
  • Aries Arditi
  • Lyndon da Cruz
  • Gislin Dagnelie
  • Jessy D Dorn
  • Jacque L Duncan
  • Allen C Ho
  • Lisa C Olmos de Koo
  • José‐Alain Sahel
  • Paulo E Stanga
  • Gabriele Thumann
  • Vizhong Wang
  • Robert J Greenberg
چکیده

OBJECTIVE The purpose of this analysis was to compare observer-rated tasks in patients implanted with the Argus II Retinal Prosthesis System, when the device is ON versus OFF. METHODS The Functional Low-Vision Observer Rated Assessment (FLORA) instrument was administered to 26 blind patients implanted with the Argus II Retinal Prosthesis System at a mean follow-up of 36 months. FLORA is a multi-component instrument that consists in part of observer-rated assessment of 35 tasks completed with the device ON versus OFF. The ease with which a patient completes a task is scored using a four-point scale, ranging from easy (score of 1) to impossible (score of 4). The tasks are evaluated individually and organised into four discrete domains, including 'Visual orientation', 'Visual mobility', 'Daily life and 'Interaction with others'. RESULTS Twenty-six patients completed each of the 35 tasks. Overall, 24 out of 35 tasks (69 per cent) were statistically significantly easier to achieve with the device ON versus OFF. In each of the four domains, patients' performances were significantly better (p < 0.05) with the device ON versus OFF, ranging from 19 to 38 per cent improvement. CONCLUSION Patients with an Argus II Retinal Prosthesis implanted for 18 to 44 months (mean 36 months), demonstrated significantly improved completion of vision-related tasks with the device ON versus OFF.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Detection of Motion by Blind Subjects With the Epiretinal 60-Electrode (Argus II) Retinal Prosthesis.

OBJECTIVE To investigate the ability of 28 blind subjects implanted with a 60-electrode Argus II (Second Sight Medical Products Inc) retinal prosthesis system to detect the direction of a moving object. METHODS Blind subjects (bare light perception or worse in both eyes) with retinitis pigmentosa were implanted with the Argus II prosthesis as part of a phase 1/2 feasibility study at multiple ...

متن کامل

Feasibility of Structural and Functional MRI Acquisition with Unpowered Implants in Argus II Retinal Prosthesis Patients: A Case Study.

PURPOSE Magnetic resonance imaging (MRI) can measure the effects of vision loss and recovery on brain function and structure. In this case study, we sought to determine the feasibility of acquiring anatomical and functional MRI data in recipients of the Argus II epiretinal prosthesis system. METHODS Following successful implantation with the Argus II device, two retinitis pigmentosa (RP) pati...

متن کامل

Visual BOLD Response in Late Blind Subjects with Argus II Retinal Prosthesis

Retinal prosthesis technologies require that the visual system downstream of the retinal circuitry be capable of transmitting and elaborating visual signals. We studied the capability of plastic remodeling in late blind subjects implanted with the Argus II Retinal Prosthesis with psychophysics and functional MRI (fMRI). After surgery, six out of seven retinitis pigmentosa (RP) blind subjects we...

متن کامل

Visual and Non-Visual Navigation in Blind Patients with a Retinal Prosthesis

Human adults with normal vision can combine visual landmark and non-visual self-motion cues to improve their navigational precision. Here we asked whether blind individuals treated with a retinal prosthesis could also benefit from using the resultant new visual signal together with non-visual information when navigating. Four patients (blind for 15-52 years) implanted with the Argus II retinal ...

متن کامل

Clinical Trials Use of the Argus II Retinal Prosthesis to Improve Visual Guidance of Fine Hand Movements

METHODS. A total of 21 patients with retinitis pigmentosa (RP), remaining vision no more than bare light perception, and an implanted Argus II epiretinal prostheses used a touchscreen to trace white paths on black backgrounds. Sets of paths were divided into three categories: right-angle/single-turn, mixedangle/single-turn, and mixed-angle/two-turn. Subjects trained on paths by using prosthetic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 99  شماره 

صفحات  -

تاریخ انتشار 2016