Spatial domain method for the design of RF pulses in multicoil parallel excitation.

نویسندگان

  • William Grissom
  • Chun-yu Yip
  • Zhenghui Zhang
  • V Andrew Stenger
  • Jeffrey A Fessler
  • Douglas C Noll
چکیده

Parallel excitation has been introduced as a means of accelerating multidimensional, spatially-selective excitation using multiple transmit coils, each driven by a unique RF pulse. Previous approaches to RF pulse design in parallel excitation were either formulated in the frequency domain or restricted to echo-planar trajectories, or both. This paper presents an approach that is formulated as a quadratic optimization problem in the spatial domain and allows the use of arbitrary k-space trajectories. Compared to frequency domain approaches, the new design method has some important advantages. It allows for the specification of a region of interest (ROI), which improves excitation accuracy at high speedup factors. It allows for magnetic field inhomogeneity compensation during excitation. Regularization may be used to control integrated and peak pulse power. The effects of Bloch equation nonlinearity on the large-tip-angle excitation error of RF pulses designed with the method are investigated, and the utility of Tikhonov regularization in mitigating this error is demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RF Pulse Design for Parallel Excitation

1. Introduction Parallel excitation has been introduced as a means of accelerating multi-dimensional, spatially-selective excitation using multiple transmit coils, each driven by a unique RF pulse (1,2). In a manner analogous to parallel imaging, parallel excitation allows the use of a reduced excitation k-space trajectory (7) to achieve a desired excitation pattern, by exploiting the blurring ...

متن کامل

Fast and Accurate Large-Tip-Angle RF Pulse Design for Parallel Excitation Using a Perturbation Analysis of the Bloch Equation

Introduction: Designing RF pulses in parallel excitation (PTX) using the linear small-tip-angle approximation [1-3] produces distorted excitation patterns at large tip angles due to the nonlinear nature of the Bloch equation. Grissom et al [4] proposed the ‘Additive Angle’ (AA) method for large-tip-angle RF pulse as a means to improve upon the small-tip-angle approximation (STA). This iterative...

متن کامل

Parallel excitation with an array of transmit coils.

Theoretical and experimental results are presented that establish the value of parallel excitation with a transmit coil array in accelerating excitation and managing RF power deposition. While a 2D or 3D excitation pulse can be used to induce a multidimensional transverse magnetization pattern for a variety of applications (e.g., a 2D localized pattern for accelerating spatial encoding during s...

متن کامل

Compensation of concomitant Maxwell gradient effects in 3D multi-element spatially selective RF excitation

Introduction Parallel RF excitation using multi-element transmit coils is of interest to reduce pulse duration for spatially selective excitation. Originally, RF pulse design was formulated in the frequency domain for arbitrary k-space trajectories (Transmit-SENSE, [1]) or in the spatial domain for echo-planar trajectories [2]. Later, Transmit-SENSE was formulated in the spatial domain in [3] a...

متن کامل

Robust Parallel Excitation Pulse Design

Introduction Parallel excitation employs multiple transmit channels and coils, each driven by independent waveforms, to afford the pulse designer an additional spatial encoding mechanism, i.e., transmit sensitivity encoding, that complements gradient encoding. However, in contrast to parallel reception, parallel excitation requires individual high-power amplifiers for each transmit channel, whi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 56 3  شماره 

صفحات  -

تاریخ انتشار 2006