Optical functional properties of the Boston Keratoprosthesis.

نویسندگان

  • Rony R Sayegh
  • Linda Avena Diaz
  • Fernando Vargas-Martín
  • Robert H Webb
  • Claes H Dohlman
  • Eli Peli
چکیده

PURPOSE To evaluate the optical characteristics of the Boston Keratoprosthesis (KPro), identify glare sources, evaluate possible glare control, and examine the benefit of implantation when the fellow eye has normal vision. METHODS Computed and optical-bench-measured point spread function (PSF) and glare sources were compared. A translucent plastic cornea was used to determine the impact of glare caused by scatter in the cornea and its control with a dark-iris tinted contact lens. The effect of glare in implanted eyes was measured with a brightness acuity test (BAT), with and without the dark-iris contact lens. Computed and measured visual fields were compared. Stereopsis was measured in patients with an intact fellow eye. RESULTS Computed and measured modulation transfer functions for the KPro were found to be very close to the diffraction limit. Both the model-eye measurements and patients' BAT glare responses identified that the hazy corneal graft surrounding the KPro is the main source of glare and can be controlled with a dark-iris contact lens. The lid effectively blocks the light that would be scattered in the hazy cornea of patients in whom the type II KPro was implanted. An intact fellow eye remains the dominant eye, with better acuity, and the KPro eye supports only minimal stereo ability and does not expand the binocular visual field. CONCLUSIONS Glare can be reduced significantly with the use of a contact lens with a dark iris. Implanting the KPro in a patient whose fellow eye has normal or near normal vision does not seem to improve visual function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anterior Segment Optical Coherence Tomography for the Quantitative Evaluation of the Anterior Segment Following Boston Keratoprosthesis

OBJECTIVE To quantitatively evaluate the anterior segment using anterior segment optical coherence tomography (AS-OCT) following Boston keratoprosthesis type 1. METHODS A retrospective study consisted of AS-OCT imaging at a single time point postoperatively in 52 eyes. Main outcomes measures include anatomical and functional anterior chamber depth (ACD), angle (ACA) and peripheral and proxima...

متن کامل

Results with the Boston Type I keratoprosthesis after Acanthamoeba keratitis

Purpose To report the outcomes of implantation of the Boston Type I keratoprosthesis in three patients with Acanthamoeba keratitis (AK), a severe infection that can lead to significant visual loss. Observations Case series reporting three patients with difficult cases of AK that needed multiple corneal transplantations and glaucoma surgeries. All patients were implanted with the Boston Type I...

متن کامل

Ultra High Resolution Optical Coherence Tomography in Boston Type I Keratoprosthesis

PURPOSE To evaluate the anterior keratoprosthesis-cornea interface in eyes with Boston type I keratoprosthesis (Kpro). METHODS In a prospective non-interventional study, patients with Boston type I Kpro underwent ultra-high resolution optical coherence tomography (UHR-OCT) evaluation. The images were used to measure and describe characteristics of the anterior keratoprosthesis-cornea interfac...

متن کامل

Boston type 1 keratoprosthesis: the university of california davis experience.

PURPOSE To compare the University of California Davis experience using the Boston keratoprosthesis with the Boston Keratoprosthesis Study Group's initial report. DESIGN Retrospective chart review. PARTICIPANTS We analyzed 30 eyes of 28 patients who previously underwent Boston type 1 keratoprosthesis surgery at our institution between 2004 and 2008. METHODS Preoperative, intraoperative, an...

متن کامل

Boston type I keratoprosthesis-donor cornea interface evaluated by high-definition spectral-domain anterior segment optical coherence tomography

BACKGROUND The purpose of this study was to assess whether the resolution offered by two different, recently commercially available high-resolution, spectral-domain anterior segment optical coherence tomography (AS-OCT) instruments allows for detailed anatomic characterization of the critical device-donor cornea interface in eyes implanted with the Boston type I permanent keratoprosthesis. ME...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 51 2  شماره 

صفحات  -

تاریخ انتشار 2010