The robustness of various forms of perimetry to different levels of induced intraocular stray light.

نویسندگان

  • Roger S Anderson
  • Tony Redmond
  • D Rodney McDowell
  • Karen M M Breslin
  • Margarita B Zlatkova
چکیده

PURPOSE To compare directly the robustness of standard automated perimetry (SAP), short-wavelength automated perimetry (SWAP), frequency-doubling perimetry (FDP), and grating-resolution perimetry (GRP) stimuli to different degrees of intraocular stray light induced by commercially available opacity-containing filters. METHODS Five white opacity filters of increasing density were used to simulate the typical forward light scatter and stray light values associated with age-related lens opacification and significant cataract. The individually induced intraocular stray light value for each filter was quantified with a stray light meter and plotted against individual perimetric thresholds for the right eyes of three normally sighted trained observers for SAP, SWAP, FDP, and GRP. RESULTS All tests were significantly but differently affected by increasing stray light. Overall average declines over a 1 log unit change in the stray light values were as follows: SAP, 4.85 dB; SWAP, 9.03 dB; FDP, 4.29 dB; and GRP, 1.36 dB. Standardized (z) scores were calculated after normalization to the spread of the normative data values for each instrument. These indicated that the standardized changes from baseline over the range of the five filters per log stray light unit were as follows: SAP, 2.177; SWAP, 1.96; FDP, 1.277; and GRP, 1.04. CONCLUSIONS The increased stray light values induced by cataract-simulating filters has a significant effect on all tests. However, GRP, which is known to be limited by retinal sampling rather than contrast, remains the most robust of the tests to the effects of intraocular stray light. The degree to which the normative "sensitivity" range for different types of perimetry might incorporate a component caused by individual differences in intraocular stray light is discussed and requires further research.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Different Levels of Intraocular Stray Light on Kinetic Perimetry Findings

PURPOSE To evaluate the effect of different levels of intraocular stray light on kinetic perimetry findings. METHODS Twenty-five eyes of 25 healthy young participants were examined by automated kinetic perimetry (Octopus 900) using Goldmann stimuli III4e, I4e, I3e, I2e, and I1e. Each stimulus was presented with a velocity of 3°/s at 24 meridians with 15° intervals. Four levels of intraocular ...

متن کامل

Light scatter and disability glare after intraocular lens implantation.

F orward light scatter measurement provides information about optical imperfections as the cause of glare disability. Glare disability refers to a reduction in visual performance caused by a glare source, resulting in retinal contrast loss secondary to intraocular stray light. Lens extraction reverses the strong age increase in stray light, which is considered an independent source of symptoms....

متن کامل

The effect of induced intraocular straylight on perimetric tests.

PURPOSE To investigate the effect of intraocular straylight (IOS) on threshold measurements made by four types of perimetry: standard automated perimetry (SAP), frequency-doubling technology (FDT) perimetry, flicker-defined form (FDF) perimetry, and the Moorfields Motion Displacement Test (MDT). METHODS Six healthy young (21-29 years) psychophysically experienced observers were tested five ti...

متن کامل

Effects of ascorbic acid on physiological and biochemical responses of Zinnia elegans L. to different levels of light intensity

The aim of this study was to investigate the effect of different light intensities and ascorbic acid on some physiological and biochemical characteristics of Zinnia elegans L. The experiment was designed as a completely randomized design in a form of split-plot with three replications. The treatments were consisted of three light intensity levels (600, 1200 and 1800 μmol m-2 s-1) as the main fa...

متن کامل

Intraspecific Variation in Leishmania major Isolated from Different Forms of Zoonotic Cutaneous Leishmaniasis

Background: Zoonotic cutaneous leishmaniasis (ZCL) is a polymorphic disease which may show various clinical manifestations. Although genetic variability of the parasite is suggested to be one of the factors influencing clinical manifestations in leishmaniasis, no data exist regarding genetic polymorphism of Leishmania major. Therefore, determination of genetic variation within the species of L....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 50 8  شماره 

صفحات  -

تاریخ انتشار 2009