Internal dosimetry estimates using voxelized reference phantoms for thyroid agents

نویسندگان

  • E. Hoseinian-Azghadi
  • L. Rafat-Motavalli
  • H. Miri-Hakimabad
چکیده

This work presents internal dosimetry estimates for diagnostic procedures performed for thyroid disorders by relevant radiopharmaceuticals. The organ doses for (131)Iodine, (123)Iodine and (99m)Tc incorporated into the body were calculated for the International Commission on Radiological Protection (ICRP) reference voxel phantoms using the Monte Carlo transport method. A comparison between different thyroid uptakes of iodine in the range of 0-55% was made, and the effect of various techniques for administration of (99m)Tc on organ doses was studied. To investigate the necessity of calculating organ dose from all source regions, the major source organ and its contribution to total dose were specified for each target organ. Moreover, we compared effective dose in ICRP voxel phantoms with that in stylized phantoms. In our method, we directly calculated the organ dose without using the S values or SAFs, as is commonly done. Hence, a distribution of the absorbed dose to entire tissues was obtained. The chord length distributions (CLDs) were also computed for the selected source-target pairs to make comparison across the genders. The results showed that the S values for radionuclides in the thyroid are not sufficient for calculating the organ doses, especially for (123)I and (99m)Tc. The thyroid and its neighboring organs receive a greater dose as thyroid uptake increases. Our comparisons also revealed an underestimation of organ doses reported for the stylized phantoms compared with the values based on the ICRP voxel phantoms in the uptake range of 5-55%, and an overestimation of absorbed dose by up to 2-fold for Iodine administration using blocking agent and for (99m)Tc incorporation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Developing the Adult Male ICRP Phantom and Evaluation the Absorbed Dose Received By Critical Organs in Head and Neck Region during the Radiotherapy of Eye Cancer

Introduction Accurate estimation of the absorbed dose in radiosensitive organs, located away from the target volume during radiotherapy, is one of the main reasons for the development of reference phantoms. The International Commission on Radiological Protection (ICRP) reference phantoms can provide a more realistic view of the human anatomy in comparison with the previously used mathematical p...

متن کامل

Internal dosimetry of radioiodine using ICRP reference phantoms and updated biokinetic model

The purpose of this study is to estimate internal dose to human body due to administration of I-131 using new biokinetic model of iodine. In this respect, we used international commission on radiological protection (ICRP) adult reference phantoms. Monte Carlo calculations were performed using MCNPX 2.6 code. The average dose to target organ per disintegration inside source organ, namely S facto...

متن کامل

Development of Iranian Adult Female Reference Phantom for Internal Dosimetry Calculations

Estimation of organ doses in diagnostic and therapeutic nuclear medicine procedures is an area of particular concern for radiation protection, in all over the world. The stylized computational phantoms have contributed significantly to radiation dosimetry in nuclear medicine; however, their simplified treatment of human anatomy is being criticized. Due to the fact that the ICRP adult reference ...

متن کامل

Development of Prototype Iranian male pelvic phantom for internal dosimetry

Introduction: Existing phantoms have been constructed based on Caucasian, non-Caucasian and race-specific datasets. According to previous studies made efforts to present Korean- specific phantoms and Chinese female phantom based on CVH dataset due to compare the resulting internal dosimetry with the Caucasian based data showed possible racial difference in human anatomy between ...

متن کامل

Development of a 9-months pregnant hybrid phantom and its internal dosimetry for thyroid agents

As a consequence of fetal radiosensitivity, the estimation of internal dose received by a fetus from radiopharmaceuticals applied to the mother is often important in nuclear medicine. A new 9-months pregnant phantom based on magnetic resonance (MR) images tied to the International Commission on Radiological Protection (ICRP) reference voxel phantom has been developed. Maternal and fetal organs ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 55  شماره 

صفحات  -

تاریخ انتشار 2014