Biomechanical Evaluation of Two Methods of Humeral Shaft Fixation
نویسنده
چکیده
This study compared the biomechanical performance of 4.5-mm limited-contact dynamic compression plates and 3.5-mm locking compression plates for the fixation of unstable humeral shaft fractures. Composite humeri were divided into two groups: 3.5mm LC and 4.5-mm LCDC plates. Osteotomy gaps of 5-mm, simulating diaphyseal comminution, were created. Stiffness tests were performed in anterior-posterior bending, medial-lateral bending, torsion, and axial compression. Results showed that while construct stiffnesses in ML bending and torsional loading are significantly higher for 4.5 LCDC plates (p < 0.05), no statistically significant differences were observed in AP bending or axial compression. Fatigue characteristics under cyclic AP bending conditions were also evaluated, although no failures occurred. Data from the literature suggest that stiffness results for the LC plate constructs perhaps afford sufficient fixation strength capable of supporting the physiologic loads most commonly applied during postoperative rehabilitation. However, results indicate that the 4.5 LCDC plating system is mechanically advantageous for stabilizing diaphyseal comminuted fractures.
منابع مشابه
Treatment Outcome of Intramedullary Fixation with a Locked Rigid Nail in Humeral Shaft Fractures
Background: The aim of this study was to determine the treatment outcome of humeral shaft fractures with a locked rigid intramedullary nail in patients indicated for surgical treatment. Methods: In this descriptive-cross sectional study, all patients were followed up for one, six, and 18 months post operatively. The Short Form Questionnaire (SF-36) and Constant Shoulder Score were applied. Re...
متن کاملBiomechanical evaluation of a novel dualplate fixation method for proximal humeral fractures without medial support
BACKGROUND Comminuted fractures of the proximal humerus are generally treated with the locking plate system, and clinical results are satisfactory. However, unstable support of the medial column results in varus malunion and screw perforation. We designed a novel medial anatomical locking plate (MLP) to directly support the medial column. Theoretically, the combined application of locking plate...
متن کاملAcute Combined Median and Radial Nerve Palsies after Distal Humeral Shaft Fracture
We report a case of a 29-year-old man who presented with a distal humeral shaft fracture sustained by blunt trauma. Physicalexamination and nerve conduction study were consistent with injury to the median and radial nerves proximal to theelbow. The patient underwent open reduction and internal fixation of the humeral shaft fracture with neurolysis of the medianand radial nerves. Repeat electrom...
متن کاملنتایج درمان شکستگی تنه هومروس به روش میلهگذاری اینترمدولاری
Background & Aim: Most acute humeral shaft fractures can be successfully treated by conservative methods. Operation is recommended for certain fractures. Intramedullary nailing offers a dependable solution for the treatment of humeral shaft fractures, especially in polytrauma patients. The aim of this study was to evaluate intramedullary nailing outcomes and complications in humeral fractur...
متن کاملBiomechanical analysis of blade plate versus locking plate fixation for a proximal humerus fracture: comparison using cadaveric and synthetic humeri.
OBJECTIVE To compare the mechanical stability of a fixed-angle blade plate with that of a locking plate in a cadaveric proximal humerus fracture-fixation model subjected to cyclic loading. A secondary objective was to evaluate whether the use of synthetic humerus specimens would replicate significant differences found during cadaveric tests. DESIGN Mechanical evaluation of constructs in bendi...
متن کامل