BACKGROUND Pulmonary function tests are valuable measures for diagnosis and management of respiratory diseases. In the field of occupational medicine, spirometry is commonly performed, and in a considerable number of spirometries during occupational health evaluations, restrictive pattern is observed without any respiratory symptoms and may necessitate referral of the subject for body plethysmography, which is an expensive test. In this study, we evaluated the diagnostic accuracy of spirometry for detection of restrictive lung pattern in an occupational setting. MATERIALS AND METHODS In a cross-sectional study from 2008 to 2012, 1224 subjects were selected and entered in the study out of 1,486 individuals referred for annual spirometry. Selected subjects underwent spirometry and body plethysmography. Subjects were divided into two groups of restrictive and non-restrictive patterns and then sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of spirometry for detection of restrictive lung pattern were calculated using total lung capacity measured by plethysmography as the gold standard. Receiver operating characteristic (ROC) curves were used as well. RESULTS Spirometry showed sensitivity, specificity, PPV and NPV of 97.75%, 73.04%, 73.72% and 97.67% for FVC< lower limit of normal (LLN) and 98.68%, 78.00%, 77.31% and 98.83% for FVC< LLN along with FEV1/FVC≥ LLN, respectively. According to the ROC curve, the best cut-off point for FVC for detection of restrictive lung pattern was 70%. CONCLUSION This study showed that spirometry is a useful method in occupational health evaluations to rule out restrictive lung patterns with acceptable accuracy; however, it is not an accurate tool for detection of restrictive lung pattern in an occupational setting. Simultaneous use of FVC and FEV1/FVC for detection of restriction increases the predictive value of spirometry.
منابع مشابه
An approach to interpreting restrictive spirometric pattern results in occupational settings.
OBJECTIVES The aim of this review is to provide an updated overview of definition, epidemiology, diagnostic algorithm and occupational exposures related to abnormal restrictive spirometrical pattern (RSP) in order to improve the correct interpretation of spirometry test results by occupational healthcare providers. METHODS A review of the scientific English literature of the last 25 years was...
متن کاملSpirometric Findings in TNT Factory Workers Compared with Unexposed Controls
Background: Trinitrotoluene (TNT) is one of the most well-known and oldest explosive agents. In the recent decade, bioenvironmental, biochemical, and biological effects of TNT exposure have been more in the spotlight. In this study, we aimed to evaluate spirometric parameters in workers of a TNT factory exposed to TNT and other related fumes and dusts compared with the unexposed controls. Metho...
متن کاملطراحی سیستم فازی برای تشخیص بیماریهای ریوی براساس تنفسسنجی
Introduction: Nowadays, air pollution, occupational and industrial harmful exposure caused the increasing prevalence of lung diseases. The pulmonary function testing such as spirometry plays an important role in the diagnosis and treatment of lung diseases. Due to the increasing use of the classification system in the prediction and detection based on the test samples, diagnosis the patients an...
متن کاملSpirometry pattern and respiratory symptoms in sweepers
Introduction: Multiple and sometimes contradictory evidence exists on the relationship between dust exposure and respiratory symptoms with pulmonary disorders. The study was conducted to examine the effects of chronic exposure to street dust on the pulmonary parameters and respiratory complaints in sweepers. Methods: This cross-sectional study was conducted on 100 sweepers working in district ...
متن کاملAgreement between fixed-ratio and lower limit of normal spirometry interpretation protocols decreases with age: is there a need for a new GOLD standard?
OBJECTIVES To assess concordance between the fixed 70% ratio cutoff point with the fixed percent predicted values (Fixed-ratio) and the lower limit of normal (LLN) algorithms in interpreting spirometry results in an older population. METHODS Spirometries were interpreted using Third National Health and Nutrition Examination Survey reference equations for 2319 workers. RESULTS The Fixed-rati...