New Coated Wire Sensors for Potentiometric Determination of Gemifloxacin in Pure Form, Pharmaceutical Formulations and Biological Fluids
نویسندگان
چکیده
A simple, accurate and precise potentiometric method was developed for the determination of gemifloxacin mesylate (GFX). Three ion selective coated wire sensors have been constructed from the incorporation of (GFX) with the ion-pairing agents phosphotungstic acid (PTA), phosphomolybdic acid (PMA) and Ammonium reineckate salt (ARS). The three sensors show nearly Nernestian response over the concentration range 1.0x10 −7 -1.0 x10 −2 mol L -1 of the drug with slopes of 56.14±0.08, 57.66±0.14 and 55.06±0.32 mV decade -1 for (GFX-PTA), (GFX-PMA) and (GFX-ARS) coated wire sensors, respectively. The electrodes exhibit a fast dynamic response of 30, 15 and 20 s for a period of 30, 35 and 25 days for (GFX-PTA), (GFX-PMA) and (GFX-ARS) coated wire sensors, respectively. The sensors exhibit good selectivity for GFX with respect to some inorganic cations, amino acids and some pharmacologically related compounds. The electrodes display stable potential response in the pH range 6-9 which indicates the applicability of these electrodes in the specified range. The method is accurate and precise as indicated by the mean % recoveries 99.49±0.52, 99.56±0.41 and 99.41±0.45 for (GFX-PTA), (GFX-PMA) and (GFX-ARS) coated wire sensors, respectively. The proposed method was successfully applied for the determination of GFX in pure form, its pharmaceutical formulations and biological fluids.
منابع مشابه
Potentiometric determination of Benzydamine hydrochloride using PVC membrane and coated wire sensors in pure form, pharmaceutical compounds and biological fluids
The construction and electrochemical response characteristics of PVC membrane and coated wire sensors for the determination of Benzydamine hydrochloride (Benz) are described. PVC membrane sensors, include sensors 1, 2 and 3, and coatedwire sensors include sensors 4, 5 and 6. Sensors 1 and 4 based on benzydamine phosphotungstate (Benz-PTA) as ion-pair, sensors 2 and 5 based on benzydamine phosph...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملDevelopment of novel potentiometric sensors for determination of lidocaine hydrochloride in pharmaceutical preparations, serum and urine samples
This article is focused on the determination of lidocaine hydrochloride as a local anaesthetic drug. A potentiometric method based on modified screen-printed and modified carbon paste ion-selective electrodes was described for the determination of lidocaine hydrochloride in different pharmaceutical preparations. It was based on potentiometric titration of lidocaine hydrochloride using modified ...
متن کاملIon Selective Electrodes for Determination of Cefditoren Pivoxil in Pharmaceutical Formulations and Biological Fluids
Newly developed coated wire electrodes have been developed for determination of cefditoren pivoxil (CTP) in pure form, pharmaceutical preparations and in biological fluids. The selective electrodes were fabricated based on the incorporation of cefditoren pivoxil with the ion exchangers, phosphomolybdic acid (CTP-PMA), phosphotungstic acid (CTP-PTA) and a mixture of both (CTP-PMA/PTA). The poten...
متن کاملAl(III) Coated Wire Selective Electrode Based on 5-Bromo(salicylidene-2-aminothiophenol) Schiff Base as a New Ionophore
A new Al(III) selective membrane based on 5-bromo(salicylidene-2-amino thiophenol) as a neutral carrier in a poly(vinyl chloride) (PVC) matrix is coated on platinum wire to determine trace amounts of Al(III) ion in various samples. The sensor exhibits a good response for Al(III) ion over a wide concentration range of 5.20 × 10-7 to 1.00 × 10-2 M with Nernstian slope of 19...
متن کامل