Coronary stent restenosis rate following implantation is considerably high. The adenosine stress gated myocardial perfusion imaging (G-MPI) method has been widely used in the diagnosis, risk stratification and prognosis evaluation of coronary heart disease; however, the high cost of adenosine limits its clinical application. The aim of the present study was to investigate the efficacy of adenosine triphosphate (ATP) stress 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) G-MPI for diagnosis in-stent restenosis following coronary stent implantation. Data from 66 patients with typical angina pectoris symptoms who had undergone percutaneous coronary stent implantation >3 months prior to participation in the study were analyzed. All the patients underwent ATP stress 99mTc-MIBI G-MPI and coronary artery angiography as the criterion diagnostic standard within 1 month. The sensitivity, specificity, and accuracy of ATP stress 99mTc-MIBI G-MPI in the assessment of in-stent restenosis were calculated. In addition, Fisher's exact probability methods were used to compare differences between experimental groups. Among 66 patients with a total of 99 implanted coronary arterial branches, 39 patients (59%) with 45 coronary arteries (45%) presented in-stent restenosis. The diagnostic sensitivity, specificity, accuracy, positive predictive and negative predictive value of ATP stress 99mTc-MIBI G-MPI for assessing stent restenosis in all patients were 85, 89, 86, 92 and 80%, respectively. Similarly, these values in patients with myocardial infarction were 79, 88, 83, 88 and 78%, respectively, while in patients without myocardial infarction the values were 90, 91, 90, 95 and 83%, respectively. Therefore, the diagnostic efficacy of ATP stress 99mTc-MIBI G-MPI in patients without myocardial infarction was higher compared with those with myocardial infarction; however, no significant difference was observed between the two groups. Furthermore, the sensitivity, specificity and accuracy for diagnosing LAD stent restenosis were higher compared with LCX and RCA stent restenosis, but with no significant differences observed (P>0.05). The present results indicated that ATP stress 99mTc-MIBI G-MPI had a high clinical application value for diagnosing in-stent restenosis following coronary stent implantation as a non-invasive examination tool, with the advantages of safety and low cost.
منابع مشابه
Myocardial perfusion scintigraphy to evaluate patients after coronary stent implantation.
UNLABELLED Coronary stent implantation is an increasingly accepted revascularization method. The 20%-30% restenosis rate during the first 6 mo requires a close follow-up of the patients. Since there is very little data available defining the role of perfusion scintigraphy in the management of this population, the aim of this study was to assess the diagnostic performance of stress myocardial pe...
متن کاملUsefulness of stress myocardial perfusion imaging for evaluating asymptomatic patients after coronary stent implantation.
BACKGROUND Stent implantation in coronary angioplasty has reduced the rate of restenosis, but many patients still undergo follow-up coronary angiography (CAG). The present study was a multi-center retrospective analysis of the usefulness of stress single photon emission computed tomography (SPECT) compared with follow-up CAG in stent-implanted patients who remained asymptomatic during the follo...
متن کاملSafety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملA Novel Method of Brachytherapy Using Local Delivery of 99mTc–HMPAO for Coronary Stent Restenosis
BACKGROUND Restenosis after percutaneous coronary intervention (PCI) is a matter that still remains to be resolved. Herein, the inhibitory effect of locally delivered 99mTc-HMPAO (hexamethyl propylene amine oxime) on neointimal hyperplasia after coronary stenting was examined in a pocine model, and its safety and efficacy observed in patients with coronary stent restenosis. METHODS After a st...
متن کاملApplication of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...