Measurement of pulpal blood flow in dogs with nonradioactive colored microspheres.
نویسندگان
چکیده
The viability of dental pulp depends largely on regional blood flow, as in other organs. Measurement of absolute pulpal blood flow (PBF) and comparisons with blood flow in other organs allow the prediction of microvascular regulation in dental pulp. In previous studies, PBF was measured in dogs mainly with radioactive microspheres. However, this established technique is inaccessible to many investigators due to concerns over radiation safety and radioactive waste. To overcome these limitations, a new method has been introduced that involves the use of nonradioactive colored microspheres for measuring regional blood flow in the myocardium and in other organs in animals. However, no previous studies have investigated the use of this method to measure PBF in dogs. We attempted to determine whether blood flow in dental pulp, which comprises a small amount of the total tissue in dogs, could be measured using this technique by comparing the measured values with those for regional myocardial blood flow. Mean blood flow values were between 0.148 and 0.182 ml/min/g for dental pulp at four different sites and about 1.0 ml/min/g in regional myocardium. These values are comparable to those previously reported using radioactive microspheres. As nonradioactive colored microspheres safety permitted measurement of absolute PBF in dogs, this technique appears to be useful for research into microvascular blood flow in dental pulp.
منابع مشابه
Evaluation of nonradioactive, colored microspheres for measurement of regional myocardial blood flow in dogs.
Measurement of regional myocardial blood flow (RMBF) is crucial in experimental studies of myocardial ischemia and reperfusion in dogs. The standard measurement technique uses radioactive microspheres; however, not all institutions are able to dispose of radioactive waste and therefore cannot make use of this method. We tested a new, nonradioactive microsphere, labeled with colors instead of nu...
متن کاملOn the validity of blood flow measurement using colored microspheres.
The aim of this study was 1) to investigate the validity of repeated estimations of blood flow using colored microspheres (CMS) and 2) to develop and validate a method that permits four consecutive estimations in the same animal using nonradiolabeled microspheres (NRMS). Several mixtures of different types of microspheres were injected in dogs, with each mixture containing the radiolabeled micr...
متن کاملMeasurement of regional myocardial blood flow with multiple colored microspheres.
BACKGROUND The use of radioactive microspheres (RM) for the measurement of regional myocardial blood flow (RMBF) is limited and inaccessible to many investigators due to radiation safety concerns and radioactive waste disposal problems. Therefore, a new method for the measurement of RMBF using colored microspheres (CM) was developed. METHODS AND RESULTS Polystyrene spheres (diameter, 15 +/- 0...
متن کاملValidation of fluorescent-labeled microspheres for measurement of regional organ perfusion.
Estimations of dog lung, pig heart, and pig kidney regional perfusion by use of fluorescent-labeled microspheres were compared with measurements obtained with standard radiolabeled microspheres. Pairs of radio- and fluorescent-labeled microspheres (15 microns diam, 6 colors) were injected into a central vein of a supine anesthetized dog and the left ventricle of three supine anesthetized pigs w...
متن کاملMeasurement of myocardial blood flow by ultrafast computed tomography.
Myocardial blood flow was analyzed by radioisotope-labeled microspheres and ultrafast computed tomography (CT) in 16 closed-chest, anesthetized dogs. The first set of 10 dogs had CT and microsphere measurements before and after chromonar-induced increases in myocardial blood flow. A second set of six dogs had flows measured at control and during temporary reductions in regional flow produced by...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Bulletin of Tokyo Dental College
دوره 42 4 شماره
صفحات -
تاریخ انتشار 2001