Novel Sternal Protection Device for Cardiac Surgery Via Median Sternotomy Incision

نویسندگان

  • Silvana F. Marasco
  • David C. McGiffin
  • Adam D. Zimmet
  • Pablo C. Solis
  • Judy M. Bingham
  • Randall A. Moshinsky
چکیده

OBJECTIVE Sternal bleeding during cardiac surgery is currently controlled using bone wax or other chemical substances that may result in adverse effects and affect wound healing and recovery. The purpose of this study was to identify a safe, cost-effective, and easy-to-use technique to reduce sternal bleeding and sternal trauma during cardiac surgery. METHODS After sternotomy, a sternal protection device was placed over each hemisternal section before insertion of the retractor and remained in situ until the end of surgery. Sternal bleeding and ease of use were assessed and recorded during surgery. Sternal trauma was assessed and recorded within 5 minutes of removal of the device, and overall satisfaction (Global Impression) and any intraoperative adverse events or device malfunction were reported at surgery completion. Patients were followed up 24 hours and 4 weeks after surgery. RESULTS Twelve patients completed the study. Adverse events reported were not considered related to the device. No sternal trauma was identified in any patient. In 9 of 11 patients, sternal bleeding was reduced after insertion of the device. The device was generally considered easy to use, although some difficulty was encountered when used with the Internal Mammary Artery retractor. CONCLUSIONS Our data suggest that the device is safe and able to reduce sternal bleeding during surgery using sternal retractors. We recommend further studies in a larger population of patients with a control group to evaluate the device's ability to reduce the morbidity associated with sternal bleeding and sternal trauma.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Straight versus S-shaped sternotomy: a histologic study in the sheep model

INTRODUCTION Straight sternotomy is the most common access for open heart surgery. Techniques have been proposed for maximizing sternal stability in high-risk patients. This trend implies a growing need for newer surgical techniques. The aim of this experimental study in the sheep model is to evaluate median vs. S shaped sternotomy the feasibility of using a special device to accelerate the ste...

متن کامل

Current Challenges in the Treatment of Deep Sternal Wound Infection Following Cardiac Surgery

Median sternotomy due to its technical simplicity and excellent exposure of the heart, great vessels and pulmonary hila is the most common incision performed in cardiothoracic surgery worldwide [1]. Originally described by Julian more than 100 years ago and re-induced by Milton in 1957, median sternotomy replaced gradually thoracotomy or bilateral transverse sternothoracotomy (clamshell incisio...

متن کامل

The use of suture anchors for sternal nonunion as a new technical approach (Demircin-Dogan technique).

OBJECTIVES Various comparative studies and techniques have been described for median sternotomy closure in the literature, previously. However, some patients are still under risk of sternal dehiscence, malunion or nonunion due to intrinsic or extrinsic factors after median sternotomy closure. Sternal nonunion described as sternal pain, with clicking, instability, or both for more than 3 months ...

متن کامل

The Sternal Management Accelerated Recovery Trial (S.M.A.R.T) – standard restrictive versus an intervention of modified sternal precautions following cardiac surgery via median sternotomy: study protocol for a randomised controlled trial

BACKGROUND The routine implementation of sternal precautions to prevent sternal complications that restrict the use of the upper limbs is currently worldwide practice following a median sternotomy. However, evidence is limited and drawn primarily from cadaver studies and orthopaedic research. Sternal precautions may delay recovery, prolong hospital discharge and be overly restrictive. Recent re...

متن کامل

Facilitated aortic valve replacement with complete sternotomy and minimal skin incision using endoscopy: a case of surgical report.

Although median sternotomy is the accepted approach to the heart for cardiac surgery, minimally invasive approaches including partial sternotomies have recently been developed. However, such strategies might lead to sternal overriding, instability, and fracture or division of the internal thoracic arteries. Furthermore, a full sternotomy would be required to address unpredictable intra- or post...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017