Automation of a flocculation test for syphilis on Groupamatic equipment.
نویسندگان
چکیده
A flocculation reaction employing a cardiolipid antigen was used for syphilis screening on Groupamatic equipment in parallel with conventional screening reactions: Kolmer CF, RPCF, Kahn, Kline, and RPR. The positive samples were confirmed by FTA-200, FTA-ABS, TPI, and in some cases by TPHA. There were 5,212 known samples which had already been tested by all methods and of which 1,648 were positive, and 58,636 screened samples including 65 positives. Half of the samples in the first series were taken without anticoagulant; the remainder were collected in potassium EDTA. The percentage of false positives with the Groupamatic was about 1-4 per cent. The percentage of false negatives among positve (greater than or equal+) samples varied from 0-18 to 1-3 per cent.; on the other hand the sensitivity was less good for samples giving doubtful and/or dissociated reactions in conventional screening reactions. The specificity and sensitivity of this technique are acceptable for a blood transfusion centre. The reproducibility is excellent and the automatic reading of results accurate. Additional advantages are rapidity (340 samples processed per hour); simultaneous performance of eleven other immunohaematological reactions; no contamination between samples; automatic reading, interpretation, and print-out of results; and saving of time because samples are not filed sequentially and are automatically identified when the results are obtained. Although the importance of syphilis in blood transfusion seems small, estimates of the risk are difficult and further investigations are planned.
منابع مشابه
VDRL slide flocculation reaction for syphilis performed on active sera.
The discovery of cardiolipin (Pangborn, 1941a) as the active agent in antigens for sero-reactions for syphilis enabled the production of chemically defined antigens, composed of cardiolipin, purified lecithin (Pangborn, 1941b), and cholesterol. Among the many tube and slide flocculation reactions based on the use of cardiolipin antigens, the Venereal Disease Research Laboratory (VDRL) slide flo...
متن کاملVDRL SLIDE FLOCCULATION REACTION FOR SYPHILIS PERFORMED ON ACTIVE SERA*t
The discovery of cardiolipin (Pangborn, 1941a) as the active agent in antigens for sero-reactions for syphilis enabled the production of chemically defined antigens, composed of cardiolipin, purified lecithin (Pangborn, 1941b), and cholesterol. Among the many tube and slide flocculation reactions based on the use of cardiolipin antigens, the Venereal Disease Research Laboratory (VDRL) slide flo...
متن کاملThe VDRL tube flocculation test; a microflocculation test for syphilis using cardiolipin-lecithin-cholesterol antigen.
In an earlier paper in this Journal (Vogelsang, 1947), a new microflocculation test for syphilis described by Harris, Rosenberg, and Riedel (1946) was compared with the Wassermann reaction, the Kahn standard test, and the Meinicke clarification test in 5,556 sera. The test was found to be very useful in the diagnosis of syphilis, having a satisfactory sensitivity and a good specificity. Harris ...
متن کاملDual testing for the serodiagnosis of syphilis; an abbreviated complement-fixation method.
Since the publication of the original complementfixation test for syphilis by Wassermann, Neisser, Bruck, and Schucht (1906) and the publication of the flocculation test of Porges and Meier (1908), innumerable modifications have been described for the improvement of both diagnostic methods. The technical complexity of the former furnished an incentive for the development of the latter. Yet, des...
متن کاملEvaluation of a digital flocculation reader for the rapid plasma reagin test for the serological diagnosis of syphilis.
We described the ASiManager-AT digital flocculation reader to demonstrate concordance between visual and digital readings of the rapid plasma reagin test for detection of antibodies in the serum of patients with syphilis. A qualitative and quantitative rapid plasma reagin was performed on each serum samples giving a concordance of 98.6% and 99.7%, respectively, for reactives and 100% for nonrea...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of venereal diseases
دوره 51 4 شماره
صفحات -
تاریخ انتشار 1975