Kidney function: glomerular filtration rate measurement with MR renography in patients with cirrhosis.
نویسندگان
چکیده
PURPOSE To assess the accuracy of glomerular filtration rate (GFR) measurements obtained with low-contrast agent dose dynamic contrast material-enhanced magnetic resonance (MR) renography in patients with liver cirrhosis who underwent routine liver MR imaging, with urinary clearance of technetium 99m ((99m)Tc) pentetic acid (DTPA) as the reference standard. MATERIALS AND METHODS This HIPAA-compliant study was institutional review board approved. Written informed patient consent was obtained. Twenty patients with cirrhosis (14 men, six women; age range, 41-70 years; mean age, 54.6 years) who were scheduled for routine 1.5-T liver MR examinations to screen for hepatocellular carcinoma during a 6-month period were prospectively included. Five-minute MR renography with a 3-mL dose of gadoteridol was performed instead of a routine test-dose timing examination. The GFR was estimated at MR imaging with use of two kinetic models. In one model, only the signal intensities in the aorta and kidney parenchyma were considered, and in the other, renal cortical and medullary signal intensities were treated separately. The GFR was also calculated by using serum creatinine levels according to the Cockcroft-Gault and modification of diet in renal disease (MDRD) formulas. All patients underwent a (99m)Tc-DTPA urinary clearance examination on the same day to obtain a reference GFR measurement. The accuracies of all MR- and creatinine-based GFR estimations were compared by using Wilcoxon signed rank tests. RESULTS The mean reference GFR, based on (99m)Tc-DTPA clearance, was 74.9 mL/min/1.73 m(2) ± 27.7 (standard deviation) (range, 10.3-120.7 mL/min/1.73 m(2)). With both kinetic models, 95% of MR-based GFRs were within 30% of the reference values, whereas only 40% and 60% of Cockcroft-Gault- and MDRD-based GFRs, respectively, were within this range. MR-based GFR estimates were significantly more accurate than creatinine level-based estimates (P < .001). CONCLUSION GFR assessment with MR imaging, which outperformed the Cockcroft-Gault and MDRD formulas, adds less than 10 minutes of table time to a clinically indicated liver MR examination without ionizing radiation. SUPPLEMENTAL MATERIAL http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.11101338/-/DC1.
منابع مشابه
Semi-automated application for kidney motion correction and filtration analysis in MR renography
Introduction: Altered renal function commonly affects patients with cirrhosis, a consequence of chronic liver disease. From lowdose contrast material-enhanced magnetic resonance (MR) renography, we can estimate the Glomerular Filtration Rate (GFR), an important parameter to assess renal function. Two-dimensional MR images are acquired every 2 seconds for approximately 5 minutes during free brea...
متن کاملDynamic three-dimensional MR renography for the measurement of single kidney function: initial experience.
A three-dimensional magnetic resonance (MR) renographic method to measure single kidney glomerular filtration rate (GFR) and split renal function was developed that is based on renal signal intensity measurements during 2-3 minutes after intravenous injection of a low dose (2 mL or 0.01 mmol/kg) of gadopentetate dimeglumine. In nine subjects, single kidney MR GFR indices correlated well with te...
متن کاملDynamic contrast-enhanced MR renography for renal function evaluation in ureteropelvic junction obstruction: feasibility study.
OBJECTIVE The purpose of this study was to evaluate split renal function, estimate single-kidney renal function, and identify cause of obstruction in patients with ureteropelvic junction (UPJ) obstruction by using contrast-enhanced dynamic MR renography (MRR). MATERIALS AND METHODS Seventeen patients with UPJ obstruction underwent MRR and diuresis nuclear renography. Nuclear renography assess...
متن کاملSingle Kidney GFR Measured using 3D MR Renography and a Multicompartmental Model
Synopsis A multicompartmental tracer kinetic model permits analysis of 3D MR renography data in terms of physiologic parameters such as glomerular filtration rate. Validation studies were performed in nine subjects, in whom single kidney GFR measurements were measured using radionuclide clearance methods. Agreement between model-fit values of SKGFR and reference values was high (r=0.77). Other ...
متن کاملEstimates of glomerular filtration rate from MR renography and tracer kinetic models.
PURPOSE To compare six methods for calculating the single-kidney glomerular filtration rate (GFR) from T(1)-weighted magnetic resonance (MR) renography (MRR) against reference radionuclide measurements. MATERIALS AND METHODS In 10 patients, GFR was determined using six published methods: the Baumann-Rudin model (BR), the Patlak-Rutland method (PR), the two-compartment model without bolus disp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiology
دوره 259 2 شماره
صفحات -
تاریخ انتشار 2011