Determination of Cu, Zn, Cd and Pb in ®sh samples by slurry sampling electrothermal vaporization inductively coupled plasma mass spectrometry

نویسندگان

  • Yi-Ching Li
  • Shiuh-Jen Jiang
چکیده

Ultrasonic slurry sampling electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (USSETV-ID-ICP-MS) has been applied to the determination of Cu, Zn, Cd and Pb in several ®sh reference samples. NH4NO3 was added to the sample solution to work as a modi®er. Since the sensitivity of the elements studied in ®sh slurry and aqueous solution was quite different, isotope dilution was used for the determination of Cu, Zn, Cd and Pb in reference samples. The in ̄uences of instrument operating conditions, slurry preparation, non-spectroscopic and spectroscopic interferences on the ion signals and accuracy and precision of isotope ratio determination were reported. The isotope ratios of each element were calculated from the peak areas of each injection peak. Precision of isotope ratio determination was better than 6%. This method has been applied to the determination of Cu, Zn, Cd and Pb in dog®sh muscle reference material (DORM-2), dog®sh liver reference material (DOLT-1) and oyster tissue (NIST SRM 1566a). Accuracy was better than 19% and precision was better than 14% with ultrasonic slurry sampling and electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry. Detection limits estimated from standard addition curves were in the range of 5±50, 200±500, 8±20 and 20±50 ng gÿ1 for Cu, Zn, Cd and Pb, respectively, in different samples. # 1998 Elsevier Science B.V.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of cadmium and lead in urine by electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry.

Electrothermal vaporization isotope dilution inductively coupled plasma mass spectrometry (ETV-ID-ICP-MS) was applied to the determination of Cd and Pb in urine samples. The isotope ratios for each element in each analytical run were calculated from the peak areas of each isotope. A relatively low vaporization temperature was used, which separated the analyte from the major matrix components an...

متن کامل

Direct determination of trace impurities in niobium pentaoxide solid powder with slurry sampling fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry

A method of fluorination assisted electrothermal vaporization inductively coupled plasma mass spectrometry (FETV-ICP-MS) was developed to directly determine the trace impurities in niobium pentaoxide solid powder in which a poly(tetrafluoroethylene) (PTFE) emulsion was used as fluorinating modifier to promote the vaporization of refractory elements from a graphite furnace and to avoid the forma...

متن کامل

Measurement of the Trace Elements Cu, Zn, Fe, and Mg and the Ultratrace Elements Cd, Co, Mn, and Pb in Limited Quantity Human Plasma and Serum Samples by Inductively Coupled Plasma-Mass Spectrometry

In public health studies limited volumes of blood are often collected and stored for future hypothesis testing. Archived samples are irreplaceable and therefore it is valuable to develop analytical techniques that require minimal sample volume. This work describes the measurement of trace elements Mg, Cu, Fe, Zn and ultratrace elements Cd, Co, Mn, Pb in limited quantity (150 μL) human serum or ...

متن کامل

Heavy Metals in Urban Soils of Xuzhou, China: Spatial Distribution and Correlation to Specific Magnetic Susceptibility

The investigation of the anthropogenic contamination by heavy metals of soils is very important for environmental planning and monitoring in urban areas. In the present study, surface soils (0 20 cm) samples from 167 sampling sites in Xuzhou (China) were collected in 2010 and analyzed for heavy metals including Zn, Pb, Fe, Mn, Cu, Cd, Sr, Ba Cr, Ni and Mo via inductively coupled plasma/mass spe...

متن کامل

Trace Metals Analysis of Legal and Counterfeit Cigarette Tobacco Samples Using Inductively Coupled Plasma Mass Spectrometry and Cold Vapor Atomic Absorption Spectrometry

Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, Albany, New York, USA ABSTRACT A closed-vessel microwave-digestion method was developed for the determination of trace amounts of Be, V, Cr, Mn, Co, Ni, Cu, Zn, As, Se, Mo, Cd, Sb, Ba, Tl, and Pb by inductively coupled plasma mass spectrometry and Hg by cold-vapor atomic absorption spectrometry...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1998