A New Approach to Laminar Flowmeters
نویسندگان
چکیده
After studying the performance and characteristics of actual laminar flowmeters a new disposition for this type of sensors is proposed in such a way that the measurement errors introduced by the intrinsic nature of the device can be minimized. The preliminary study shows that the developing entry region introduces non-linearity effects in all these devices. These effects bring about not only errors, but also a change in the slope of the linear calibration respect of the Poiseuille relation. After a subsequent analysis on how these non-linearity errors can be reduced, a new disposition of this type of flowmeters is introduced. This device makes used of flow elements having pressure taps at three locations along its length and connected to three isolated chambers. In this way, the static pressure can be measured at three locations and contributed to by the pressure taps at the level of each chamber. Thus the linearization error is reduced with an additional advantage of producing a reduced pressure drop.
منابع مشابه
The Long Term Calibration Stability of Critical Flow Nozzles and Laminar Flowmeters
The National Institute of Standards and Technology (NIST) has performed calibrations of gas flowmeters using piston and bell provers for three decades. Most of the meters calibrated have been either critical flow nozzles or laminar flowmeters since these meter types are generally chosen as the working standards or transfer standards by other flow calibration laboratories. Often the same meters ...
متن کاملIncompressible laminar flow computations by an upwind least-squares meshless method
In this paper, the laminar incompressible flow equations are solved by an upwind least-squares meshless method. Due to the difficulties in generating quality meshes, particularly in complex geometries, a meshless method is increasingly used as a new numerical tool. The meshless methods only use clouds of nodes to influence the domain of every node. Thus, they do not require the nodes to be conn...
متن کاملA New Approach to Signal Processing for DC-Electromagnetic Flowmeters
Electromagnetic flowmeters with DC excitation are used for a wide range of fluid measurement tasks, but are rarely found in dosing applications with short measurement cycles due to the achievable accuracy. This paper will identify a number of factors that influence the accuracy of this sensor type when used for shortterm measurements. Based on these results a new signal-processing algorithm wil...
متن کاملDynamic Weighing Calibration Method for Liquid Flowmeters -a New Approach
In the last years, the PTB liquid flow group has been working on the development of a new method to calibrate liquid flowmeters under dynamics conditions [1,2]. Such a measurement principle is based on a dynamic weighing approach, which is able to reproduce the unit of mass flow several times, with the ultimate goal to reduce the calibration time, energy cost, and workload in liquid flow calibr...
متن کاملAn Experimental Investigation and Prediction of Asphaltene Deposition during Laminar Flow in the Pipes Using a Heat Transfer Approach
In this study, asphaltene deposition from crude oil has experimentally and theoretically been studied using a test loop and an accurate temperature monitoring during a laminar flow. The effects of oil velocity and surface temperature on the thickness of asphaltene deposition were investigated. The results show that asphaltene deposition thickness increases by increasing surface temperature. As ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 10 شماره
صفحات -
تاریخ انتشار 2010