Effects of retraction force and anchorage reinforcement on occlusal force: a model study.

نویسندگان

  • MoonHee Kim
  • Kyung-sim Seol
  • Yoonjung Lee
  • Jiman Park
  • Minji Kim
  • Youn-Sic Chun
چکیده

OBJECTIVES The aim of this study was to investigate the effects of retraction force and anchorage reinforcement with orthodontic mini implants on occlusal force. MATERIALS AND METHODS A strain gauge was attached to the palatal surface of the maxillary right first molar on an en masse retraction model. RESULTS Occlusal forces were measured from this model, according to different retraction forces that were generated by elastic chain, under varied compressive forces (simulating masticatory forces). This retraction experiment was then performed again, after using anchorage reinforcement with an orthodontic mini implant. Occlusal force decreased as retraction force increased. The decrease showed a significant difference above 150g of retraction force (P < 0.05) and was more definite under compressive force higher than 150 N (P < 0.001). After anchorage reinforcement with the orthodontic mini implant, however, occlusal force did not significantly decrease with increasing retraction force. Significant differences in occlusal force were noted between the conditions with and without anchorage reinforcement when the applied retraction force was greater than 200g. CONCLUSION Occlusal force tends to decrease during retraction, and this decrease can be prevented by anchorage reinforcement with orthodontic mini implants. LIMITATIONS Further investigation on the actual masticatory process in humans is required for more clear clinical implication.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimizing Anterior En Masse Retraction with Miniscrew Anchorage

In severely protrusive patients, skeletal anchorage from miniscrew is often used to avoid anchorage loss with preferred miniscrew location near centre of resistance (Cres) of posterior teeth. Biomechanical requirement for directing retraction force towards Cres of posterior teeth demands the insertion of miniscrew in loose mucosa, where risk of infection and failure increases. In addition, unde...

متن کامل

Maximum occlusal force relationship with head and facial pattern in dental students of Shahed university

Background and Aims: The vertical growth pattern of the face depends on several factors. One of these factors can be the muscle strength of the jaw. Maximum occlusal force (MOF) can be considered as an index to measure the function of the muscles of the masticatory system. Despite the various studies, the relationship between the facial pattern and muscle function is still controversial. Accord...

متن کامل

Second Molar Uprighting with Temporary Anchorage Devices: A Finite Element Study

BACKGROUND AND OBJECTIVE: Premature loss of mandibular first molar is a common problem in adults. Mesial tipping of second molar may occur in this situation. Various orthodontic mechanics have been proposed for molar uprighting. The aim of this study was to compare four methods of molar uprighting using Finite Element Analysis(FEM). METHODS: In first model of this finite element study, a 0.019...

متن کامل

Preprosthetic molar uprighting using skeletal anchorage.

after extraction or loss of a first molar, the second molar may tip mesially into the edentulous space. Not only will the first-molar space contract mesiodistally, but eccentric occlusal loading will reduce the biomechanical loading capacity of the second molar. Such a situation requires preprosthetic up righting of the second molar using appropriate mechanics. Simply tipping the molar distally...

متن کامل

بررسی آزمایشگاهی و صحرایی تثبیت خطوط لوله مدفون در زمین های اشباع

Large deformation causing damage due to uplift force is generated in buried pipeline located in shallow trenches in marshes and saturated soils. In this paper, existing common methods of pipeline anchorage are discussed and considering advantages and disadvantages of these methods, a new method of pipeline anchorage are studied and presented. In this new developed method, geo-textile materials ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of orthodontics

دوره 36 5  شماره 

صفحات  -

تاریخ انتشار 2014