Evaluating use of neutral electrolyzed water for cleaning near-patient surfaces.

نویسندگان

  • M Stewart
  • A Bogusz
  • J Hunter
  • I Devanny
  • B Yip
  • D Reid
  • C Robertson
  • S J Dancer
چکیده

OBJECTIVE This study aimed to monitor the microbiological effect of cleaning near-patient sites over a 48-hour period with a novel disinfectant, electrolyzed water. SETTING One ward dedicated to acute care of the elderly population in a district general hospital in Scotland. METHODS Lockers, left and right cotsides, and overbed tables in 30 bed spaces were screened for aerobic colony count (ACC), methicillin-susceptible Staphylococcus aureus (MSSA), and methicillin-resistant S. aureus (MRSA) before cleaning with electrolyzed water. Sites were rescreened at varying intervals from 1 to 48 hours after cleaning. Microbial growth was quantified as colony-forming units (CFUs) per square centimeter and presence or absence of MSSA and MRSA at each site. The study was repeated 3 times at monthly intervals. RESULTS There was an early and significant reduction in average ACC (360 sampled sites) from a before-cleaning level of 4.3 to 1.65 CFU/cm(2) at 1 hour after disinfectant cleaning ( P < .0001). Average counts then increased to 3.53 CFU/cm(2) at 24 hours and 3.68 CFU/cm(2) at 48 hours. Total MSSA/MRSA (34 isolates) decreased by 71% at 4 hours after cleaning but then increased to 155% (53 isolates) of precleaning levels at 24 hours. CONCLUSIONS Cleaning with electrolyzed water reduced ACC and staphylococci on surfaces beside patients. ACC remained below precleaning levels at 48 hours, but MSSA/MRSA counts exceeded original levels at 24 hours after cleaning. Although disinfectant cleaning quickly reduces bioburden, additional investigation is required to clarify the reasons for rebound contamination of pathogens at near-patient sites.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Antimicrobial Effect of Chitosan Coating Prepared by Neutral Electrolyzed Water against Inoculated Escherichia coli O157:H7 on Rainbow trout fillets

Background and Objectives: Nowadays, to avoid the use of synthetic preservatives, which do more harm than good, numerous studies are currently focused on using natural ingredients to enhance food product quality and shelf life. Since no study has been conducted on combining coatings with electrolyzed water containing natural antimicrobial compounds, the present study has innovation and priority...

متن کامل

Application of electrolyzed water in the food industry

Electrolyzed oxidizing (EO) water has been regarded as a new sanitizer in recent years. Production of EO water needs only water and salt (sodium chloride). EO water have the following advantages over other traditional cleaning agents: effective disinfection, easy operation, relatively inexpensive, and environmentally friendly. The main advantage of EO water is its safety. EO water which is also...

متن کامل

Bactericidal effect of electrolyzed neutral water on bacteria isolated from infected root canals.

OBJECTIVE The purposes of this study were to examine the time-related changes in pH, oxidation-reduction potential, and concentration of chlorine of electrolyzed neutral water and to evaluate the bactericidal effect of electrolyzed neutral water against bacteria from infected root canals. STUDY DESIGN Various properties of electrolyzed neutral water--pH value, oxidation-reduction potential, a...

متن کامل

Effectiveness of electrolyzed acidic water in killing Escherichia coli O157:H7, Salmonella enteritidis, and Listeria monocytogenes on the surfaces of tomatoes.

A study was conducted to evaluate the efficacy of electrolyzed acidic water, 200-ppm chlorine water, and sterile distilled water in killing Escherichia coli O157:H7, Salmonella, and Listeria monocytogenes on the surfaces of spot-inoculated tomatoes. Inoculated tomatoes were sprayed with electrolyzed acidic water, 200-ppm chlorine water, and sterile distilled water (control) and rubbed by hand f...

متن کامل

Suitability of electrolyzed oxidizing water for the disinfection of hard surfaces and equipment in radiology

BACKGROUND Hospitals are faced with increasingly resistant strains of micro-organisms. When it comes to disinfection, individual parts of electronic equipment of angiology diagnostics such as patient couches of computer tomography (CT) and magnetic resonance imaging (MRI) scanners prove to be very hard to disinfect. Disinfectants of choice are therefore expected to possess properties such as ra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Infection control and hospital epidemiology

دوره 35 12  شماره 

صفحات  -

تاریخ انتشار 2014