A randomized, open-label clinical trial using optical coherence tomography to compare two sirolimus-eluting stents, one with a biodegradable polymer and the other with a permanent polymer.

نویسندگان

  • Feng Tian
  • Yundai Chen
  • Changfu Liu
  • Qinhua Jin
  • Lian Chen
  • Zhijun Sun
  • Hongbin Liu
  • Jun Guo
  • Luyue Gai
چکیده

Intimal hyperplasia appears to differ after implanting a drug-eluting stent (DES) with a biodegradable or a permanent polymer. The aim of the present study was to compare biodegradable with permanent polymer DES, since the available data are limited. One hundred patients with de novo coronary artery stenosis were included in this study. The patients were classified into 2 groups: DES with a biodegradable polymer (n=50) and DES with a permanent polymer (n=50). Optical coherence tomography (OCT) examination was performed before and after stent implantation. A follow‑up OCT, performed 1 year after stent implantation, compared the morphologies of intimal hyperplasia in the 2 groups. The frequencies of uncovered stent struts (2.27 vs. 1.87%, P=0.145) and stent strut malapposition (1.9 vs. 2.02%, P=0.655) upon the first-year follow-up were not significantly different. Average neointimal thickness was lower in the biodegradable compared with the permanent polymer group (106.12±80.65 vs. 181.20±146.96 µm, P<0.001). The frequencies of neointimal thickness <100 µm were significantly higher in the biodegradable compared with the permanent polymer group (62.1 vs. 35.9%, P<0.001). The average intimal thickness was also lower in the biodegradable compared with the permanent polymer group (57.7±24.6 vs. 67.6±22.4 µm, P<0.001). In conclusion, biodegradable polymer DES resulted in significantly lower intimal hyperplasia and had well-proportioned intimal coverage compared with permanent polymer DES.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Baremetal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis OPEN ACCESS

Objective To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. Design Mixed treatment comparison meta-analysis of 258 544 patient years of follow-up from randomized trials. Data sources and study selection PubMed, Embase, and Central were searched for randomized trials comparing any of the Food a...

متن کامل

Two-year outcome of a randomized trial comparing second-generation drug-eluting stents using biodegradable or durable polymer.

Two-Year Outcome of a Randomized Trial Comparing Second-Generation Drug-Eluting Stents Using Biodegradable or Durable Polymer Recentnetworkmeta-analyseshave raisedconcerns about the safety of biodegradable polymerdrug-eluting stents (BP-DES) compared with durable polymer everolimus-eluting stents (DP-EES).1-3 The NOBORI Biolimus-Eluting vs XIENCE/ PROMUSEverolimus-ElutingStentTrial (NEXT) is a9...

متن کامل

Vessel healings after stenting with different polymers in STEMI patients

BACKGROUND Different stents implantation in ST-segment elevation myocardial infarction (STEMI) patients may influence the long term prognosis by affecting vessel healings after stenting. The aim of this study was to evaluate the vessel healings after implantation of drug eluting stents (DES) with biodegradable or durable polymer or of bare-metal stents (BMS) in patients with acute STEMI. METH...

متن کامل

Comparison of a novel biodegradable polymer sirolimus-eluting stent with a durable polymer everolimus-eluting stent: results of the randomized BIOFLOW-II trial.

BACKGROUND Biodegradable polymers for release of antiproliferative drugs from drug-eluting stents aim to improve vascular healing. We assessed noninferiority of a novel ultrathin strut drug-eluting stent releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) compared with the durable polymer Xience Prime everolimus-eluting stent (X-EES) in terms of the primary end point in-stent late ...

متن کامل

Bare metal stents, durable polymer drug eluting stents, and biodegradable polymer drug eluting stents for coronary artery disease: mixed treatment comparison meta-analysis

OBJECTIVE To compare the efficacy and safety of biodegradable polymer drug eluting stents with those of bare metal stents and durable polymer drug eluting stents. DESIGN Mixed treatment comparison meta-analysis of 258,544 patient years of follow-up from randomized trials. DATA SOURCES AND STUDY SELECTION PubMed, Embase, and Central were searched for randomized trials comparing any of the Fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Molecular medicine reports

دوره 7 4  شماره 

صفحات  -

تاریخ انتشار 2013