The Analytic Signal Magnitude for Improved Ultrasonic Signatures
نویسنده
چکیده
Conventional pulse-echo ultrasonic receivers rectify the received signal. Because the signature of the reflecting interfaces is modulated by the predominant ultrasonic frequency, interpretation of this signal in terms of the structure of the reflecting interfaces is difficult. Smoothing, as by an R-C filter, ameliorates this effect, giving a less confusing display at the expense of resolution. The magnitude of the analytic signal, on the other hand, represents the shape of the energy packets arriving from the reflecting interfaces. Since this signature is free of modulation effects, interpretation of the signal in terms of the reflecting interfaces is more straightforward. Furthermore, smoothing is not normally needed. The analytic signal magnitude can be obtained by several means. The implementation used in this study is particularly suited for digital data processing. The Hilbert Transform of the received signal (the "real part") is obtained with the aid of the Fast Fourier Transform. This produces the quadrature component (the "imaginary part"). The magnitude is calculated from both these components. In contrast to signal processing techniques involving deconvolution, this technique is surprisingly robust with respect to noise and quantization. Typical signatures obtained with this technique are demonstrated.
منابع مشابه
An improved method for geological boundary detection of potential field anomalies
Potential field methods such as gravity and magnetic methods are among the most applied geophysical methods in mineral exploration. A high-resolution technique is developed to image geologic boundaries such as contacts and faults. Potential field derivatives are the basis of many interpretation techniques. In boundary detection, the analytic signal quantity is d...
متن کاملMonitoring Pipe-Wall Corrosion Rate by Ultrasonic Technique
thickness and corrosion/erosion rate. In this thesis, a combination of signal processing techniques are used to estimate the corrosion rate estimates based on MBE. Corrosion rate is estimated based on ultrasonic pipe wall thickness data is collected over a short period of time using MBE model. This technique is based on data collected from the speedometer applied for thinning and both indicate ...
متن کاملروشی نوین در کاهش نوفه رایسین از مقدار بزرگی سیگنال دیفیوژن در تصویربرداری تشدید مغناطیسی (MRI)
The true MR signal intensity extracted from noisy MR magnitude images is biased with the Rician noise caused by noise rectification in the magnitude calculation for low intensity pixels. This noise is more problematic when a quantitative analysis is performed based on the magnitude images with low SNR(<3.0). In such cases, the received signal for both the real and imaginary components will fluc...
متن کاملExperimental and numerical study of delamination detection in a WGF/epoxy composite plate using ultrasonic guided waves and signal processing tools
Reliable damage detection is one of the most critical tasks in composite plate structures. Ultrasonic guided waves are acknowledged as an effective way of structural health mo...
متن کاملAn Improved Standard Cell Placement Methodology using Hybrid Analytic and Heuristic Techniques
In recent years, size of VLSI circuits is dramatically grown and layout generation of current circuits has become a dominant task in design flow. Standard cell placement is an effective stage of physical design and quality of placement affects directly on the performance, power consumption and signal immunity of design. Placement can be performed analytically or heuristically. Analytical placer...
متن کامل