Manual in-line stabilization increases pressures applied by the laryngoscope blade during direct laryngoscopy and orotracheal intubation.

نویسندگان

  • Brandon G Santoni
  • Bradley J Hindman
  • Christian M Puttlitz
  • Julie B Weeks
  • Nathaniel Johnson
  • Mazen A Maktabi
  • Michael M Todd
چکیده

BACKGROUND Manual in-line stabilization (MILS) is recommended during direct laryngoscopy and intubation in patients with known or suspected cervical spine instability. Because MILS impairs glottic visualization, the authors hypothesized that anesthesiologists would apply greater pressure during intubations with MILS than without. METHODS Nine anesthetized and pharmacologically paralyzed patients underwent two sequential laryngoscopies and intubations, one with MILS and one without, in random order. A transducer array along a Macintosh 3 laryngoscope blade continuously measured applied pressures, and glottic view was characterized. RESULTS With MILS, glottic visualization was worse in six patients, and intubation failure occurred in two of these six patients. Maximum laryngoscope pressure at best glottic view was greater with MILS than without (717 +/- 339 mmHg vs. 363 +/- 121 mmHg, respectively; n = 8; P = 0.023). Other measures of pressure application also indicated comparable increases with MILS. CONCLUSION Pressures applied to airway tissues by the laryngoscope blade are secondarily transmitted to the cervical spine and result in cranio-cervical motion. In the presence of cervical instability, impaired glottic visualization and secondary increases in pressure application with MILS have the potential to increase pathologic cranio-cervical motion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

All glucose measurements are not equal.

1. Santoni BG, Hindman BJ, Puttlitz CM, Weeks JB, Johnson N, Maktabi MA, Todd MM: Manual in-line stabilization increases pressures applied by the laryngoscope blade during direct laryngoscopy and orotracheal intubation. ANESTHESIOLOGY 2009; 110:24–31 2. Nolan JP, Wilson ME: Orotracheal intubation in patients with potential cervical spine injuries. An indication for the gum elastic bougie. Anaes...

متن کامل

Effects of cervical spine immobilization technique and laryngoscope blade selection on an unstable cervical spine in a cadaver model of intubation.

STUDY OBJECTIVE Orotracheal intubation (OTI) is commonly used to establish a definitive airway in major trauma victims, with several different cervical spine immobilization techniques and laryngoscope blade types used. This experimental, randomized, crossover trial evaluated the effects of manual in-line stabilization and cervical collar immobilization and 3 different laryngoscope blades on cer...

متن کامل

Laryngoscopy force, visualization, and intubation failure in acute trauma: should we modify the practice of manual in-line stabilization?

CERVICAL spine stabilization during transport and general care reduced secondary neurologic injury from 10– 25% to 1–3%. This experience led airway managers to adopt manual in-line stabilization (MILS) during direct laryngoscopy (DL). Although MILS is intuitively appealing, there is, as Santoni et al. state in this issue of ANESTHESIOLOGY, “no objective evidence of benefit.” Substantial ethical...

متن کامل

Measurement of Pressure between Upper Airway Tract and Laryngoscope Blade during Orotracheal Intubation with Film of Microcapsules

The measurement system for the pressure between the blade of a laryngoscope and the upper airway tract during orotracheal intubation has been investigated with a film of microcapsules. Two types of the laryngoscope were used in the study: WisForegger and Mac-Intosh. The film is attached on the surface of the blade of the laryngoscope. The measurement was applied to 20 cases of the orotracheal i...

متن کامل

Severe bradycardia during suspension laryngoscopy performed after tracheal intubation using a direct laryngoscope with a curved blade -A case report-

There are a few reports about bradycardia or asystole caused by direct laryngoscopy. However, we encountered severe bradycardia in response to suspension laryngoscopy for laryngeal polypectomy after safely completing tracheal intubation using a direct laryngoscope with a curved blade. The tip of the curved blade of the direct laryngoscope is positioned at the vallecula (between the base of the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 110 1  شماره 

صفحات  -

تاریخ انتشار 2009