The relationship between initial implant stability quotient values and bone-to-implant contact ratio in the rabbit tibia
نویسندگان
چکیده
PURPOSE Implant stability quotient (ISQ) values have been supposed to predict implant stability. However, the relationship between ISQ values and bone-to-implant contact ratio (BIC%) which is one of the predictors of implant stability is still unclear. The aim of the present study was to evaluate initial ISQ values in relation to BIC% using rabbit model. MATERIALS AND METHODS Four New Zealand white rabbits received a total of 16 implants in their tibia. Immediately after implant placement ISQ values were assessed. The measurements were repeated at the time of sacrifice of the rabbits after 4 weeks. Peri-implant bone regeneration was assessed histomorphometrically by measuring BIC% and bone volume to total volume values (bone volume %). The relationships between ISQ values and the histomorphometric output were assessed, and then, the osseointegration prediction model via the initial ISQ values was processed. RESULTS Initial ISQ values showed significant correlation with the BIC%. The bone volume % did not show any significant association with the ISQ values. CONCLUSION In the limitation of this study, resonance frequency analysis is a useful clinical method to predict the BIC% values and examine the implant stability.
منابع مشابه
تحلیل پایداری ایمپلنت دندانی و بررسی تاثیر عوامل موثر بر اتصال ایمپلنت- استخوان به کمک مدل اصطکاکی تماس
Background and Aims: Relative displacement of the implant with respect to bone and quality of bone-implant contact play critical roles in the dental implant stability. The goal of this study was to investigate the dental implant stability using non-linear finite elements method. Therefore, bone-implant relative displacement due to applied force to the implant was calculated, and then an appropr...
متن کاملبررسی هیستولوژیک و هیستومرفومتریک استخوانسازی در مجاورت ایمپلنت تیتانیوم با و بدون Bio-oss در فضای مدولاری درشتنی خرگوش
Background and Objective: Nowadays, various biomaterials have been presented for regeneration of osseous defects and Bio-oss is one of them. The objective of this study was evaluation of Bio-oss function in intramedullary space of rabbit`s tibia near titanium implant. Materials and Methods: In this study, 12 white New Zealand rabbits were selected and randomly divided into control and experimen...
متن کاملResonance frequency analysis of implant stability in augmented and non-augmented sinus sites
Background and aim: Although there have been substantial developments in dental implant therapies, achieving good implant stability (ISQ >60) for implants inserted in augmented sinus sites appears to be challenging in comparison with non-augmented sites due to the high prevalence of bone resorption in posterior regions of maxilla. This study aimed to evaluate and compare the time required to a...
متن کاملComparison of Implant Stability in Sinus Lift Surgery Using Autogenous Versus Allogeneic Bone Grafts
Background and aim: The most common method of increasing implant stability in the posterior maxilla comprises the reinforcement of bone height using bone grafts in sinus lift surgery. The purpose of the present study was to compare autogenous and allogeneic bone grafts in implant stability after open sinus lift surgery. Materials and methods: This split-mouth clinical trial compared the implant...
متن کاملCorrelation of Anthropometric Measurements of Proximal Tibia in Iranian Knees with Size of Current Tibial Implants
of the Caucasian population. The purpose of this study was to investigate the morphometry of the proximal tibia in thestandard resected surface of total knee arthroplasty (TKA).Methods: In this descriptive study, the anthropometric data of the proximal tibia were measured in 132 knees (80 malesand 52 females) using magnetic resonance imaging in 2015. The collected data include...
متن کامل