MR of Ballistic Materials : Imaging

نویسندگان

  • Alison S. Smith
  • Gregory C. Hurst
  • Jeffrey L. Duerk
  • Pedro J. Diaz
چکیده

The most common ballistic materials available in the urban setting were studied for their MR effects on deflection force, rotation, heating, and imaging artifacts at 1.5 T to determine the potential efficacy and safety for imaging patients with ballistic injuries. The 28 missiles tested covered the range of bullet types and materials suggested by the Cleveland Police Department. The deflection force was measured by the New method. Rotation was evaluated 30 min after bullets had been placed in a 10% (weight per weight) ballistic gelatin designed to simulate brain tissue, with the long axis of the bullet placed parallel and perpendicular to the i axis of the magnet. Heating was measured with alcohol thermometers by imaging for 1 hr alternatively with gradientecho and spin-echo sequences (RF absorption = 0.033 and 0.326 w /kg respectively). Image artifacts on routine sequences were evaluated. All the steel-containing bullets except for the Winchester armor-piercing 38 caliber exhibited deflection. A nonsteel 7.38-mm Mauser also deflected. Deflection range was 514 to 15,504 dynes. Rotation occurred when the bullets were not parallel to the Z axis. Temperature changes were not significant. Deflecting projectiles resulted in obliteration of the image. The artifacts from other projectiles were small but varied by content. The artifact of the Winchester armor-piercing 38-caliber bullet was similar to those without steel. Bullets that contain steel or ferromagnetic contaminates such as nickel can be rotated within the MR unit. Ferromagnetic contaminants do not allow nonsteel bullets to be imaged with confidence; the potential rotation and movement of these missiles results in a relative contraindication to MR, although location within the body and time since injury may be modifying conditions. Missiles with nonaustenitic steel or nickel in the area of interest make images useless, while projectiles without these materials cause minimal image distortion and signal void.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Added value of dual-energy computed tomography versus single-energy computed tomography in assessing ferromagnetic properties of ballistic projectiles: implications for magnetic resonance imaging of gunshot victims.

OBJECTIVE The objective of this study was to assess the discriminative power of dual-energy computed tomography (DECT) versus single-energy CT (SECT) to distinguish between ferromagnetic and non-ferromagnetic ballistic projectiles to improve safety regarding magnetic resonance (MR) imaging studies in patients with retained projectiles. MATERIALS AND METHODS Twenty-seven ballistic projectiles ...

متن کامل

Recent Advances in PET-MR Hybrid contrast agent

Introduction: All of the Imaging modalities have advantages and disadvantages alone. So if we want to have the best and perfect image, combining these modalities produces something we desired. PET-MR images consist of morphologic and metabolic data. MRI and PET provide high spatial and contrast resolution and high sensitivity and molecular information respectively. Hybrid PET-...

متن کامل

Comparison of state-of-the-art atlas-based bone segmentation approaches from brain MR images for MR-only radiation planning and PET/MR attenuation correction

Introduction: Magnetic Resonance (MR) imaging has emerged as a valuable tool in radiation treatment (RT) planning as well as Positron Emission Tomography (PET) imaging owing to its superior soft-tissue contrast. Due to the fact that there is no direct transformation from voxel intensity in MR images into electron density, itchr('39')s crucial to generate a pseudo-CT (Computed Tomography) image ...

متن کامل

Spontaneous discharge of a firearm in an MR imaging environment.

An incident recently occurred at an outpatient imaging center in western New York State, in which a firearm spontaneously discharged in a 1.5-T MR imaging environment with active shielding. To our knowledge, this is the first documented case of such an occurrence. The event confirms previously reported theoretic risks of a firearm discharging in an MR imaging environment [1]. In this report, we...

متن کامل

Changes of Cortisol and Glucose Concentrations in Rats Exposed to MR Imaging Field

Background: MR imaging is one of the best diagnostic modalities in medicine. During an MR imaging examination, three types of field are employed to produce images. Various experimental studies have been performed about the effects of each single type of field but only few studies are available on their combination to generate MR imaging. The main objective of this research work is to study the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013