Development of a fast pixel array detector for use in microsecond time- resolved x-ray diffraction
نویسندگان
چکیده
A large-area pixel x-ray detector is being developed to collect eight successive frames of wide dynamic range two-dimensional images at 200kHz rates. Such a detector, in conjunction with a synchrotron radiation x-ray source, will enable time-resolved x-ray studies of proteins and other materials on time scales which have previously been inaccessible. The detector will consist of an array of fully-depleted 150 micron square diodes connected to a CMOS integrated electronics layer with solder bump-bonding. During each framing period, the current resulting from the x-rays stopped in the diodes is integrated in the electronics layer, and then stored in one of eight storage capacitors underneath the pixel. After the last frame, the capacitors are read out at standard data transmission rates. The detector has been designed for a well-depth of at least 10,000 x-rays (at 12keV), and a noise level of one x-ray. Ultimately, we intend to construct a detector with over one million pixels (1024 by 1024). We present the results of our development effort and various features of the design. The electronics design is discussed, with special attention to the performance requirements. The choice and design of the detective diodes, as they relate to x-ray stopping power and charge collection, are presented. An analysis of various methods of bump bonding is also presented. Finally, we discuss the possible need for a radiation-blocking layer, to be placed between the electronics and the detective layer, and various methods we have pursued in the construction of such a layer.
منابع مشابه
Development Of A Pixel Array Detector For Time Resolved X-ray Imaging
We are developing an integrating Pixel Array Detector (PAD) for microsecond timeresolved x-ray diffraction. The current detector prototype has a format of 92x100 pixels, each 150μm square, and covers an active area of 15x13.8 mm. The detector was tested at the CHESS D1 beamline and imaging capabilities within the microsecond time resolution regime were successfully demonstrated. This prototype ...
متن کاملTests of a prototype pixel array detector for microsecond time- resolved X-ray diffraction
G. Rossi,* M. Renzi, E. F. Eikenberry, M. W. Tate, D. Bilderback, E. Fontes, R. Wixted, S. Barna2 and S. M. Gruner Department of Physics, Cornell University, Ithaca, NY 14853, USA, Department of Pathology, Robert Wood Johnson Medical School, Piscataway, NJ 08854, USA, Cornell High Energy Synchrotron Source, Cornell University, Ithaca, NY 14853, USA, School of Applied and Engineering Physics, Co...
متن کاملX-ray analog pixel array detector for single synchrotron bunch time-resolved imaging.
Dynamic X-ray studies can reach temporal resolutions limited by only the X-ray pulse duration if the detector is fast enough to segregate synchrotron pulses. An analog integrating pixel array detector with in-pixel storage and temporal resolution of around 150 ns, sufficient to isolate pulses, is presented. Analog integration minimizes count-rate limitations and in-pixel storage captures succes...
متن کاملDevelopment of a two-dimensional virtual-pixel X-ray imaging detector for time-resolved structure research.
An interpolating two-dimensional X-ray imaging detector based on a single-photon counter with gas amplification by GEM (gas electron multiplier) structures is presented. The detector system can be used for time-resolved structure research down to the micro s time domain. The prototype detector has been tested at the SAXS (small-angle X-ray scattering) beamline at ELETTRA synchrotron light sourc...
متن کاملHigh-Speed X-ray Imaging with the Keck Pixel Array Detector (Keck PAD) for Time-Resolved Experiments at Synchrotron Sources
Modern storage rings are readily capable of providing intense x-ray pulses, tens of picoseconds in duration, millions of times per second. Exploiting the temporal structure of these x-ray sources opens avenues for studying rapid structural changes in materials. Many processes (e.g. crack propagation, deformation on impact, turbulence, etc.) differ in detail from one sample trial to the next and...
متن کامل