Five-Year Outcomes After Treatment for Acute Instability of the Tibiofibular Syndesmosis Using a Suture-Button Fixation System
نویسندگان
چکیده
BACKGROUND Suture-button repair is a widely accepted surgical treatment for acute and isolated ankle syndesmosis injuries. To our knowledge, midterm results have not previously been reported. PURPOSE To evaluate the clinical, qualitative, and quantitative radiological midterm outcomes of suture-button repair after acute isolated ankle syndesmosis injuries. STUDY DESIGN Retrospective case series; Level of evidence, 4. METHODS Clinical outcomes were measured using the Foot and Ankle Disability Index (FADI) and the American Orthopaedic Foot and Ankle Society (AOFAS) score. Three-tesla magnetic resonance imaging (MRI) was performed bilaterally at the ankle. Besides morphological sequences for evaluation of the syndesmosis and degenerative changes of the ankle using the Ankle Osteoarthritis Scoring System (AOSS), the MR protocol included a coronal 2-dimensional multislice multiecho sequence for quantitative cartilage T2-weighted mapping. Spearman correlations and paired t tests were used for statistical analysis. RESULTS This retrospective study included 19 consecutive patients (mean age, 29.7 ± 11.5 years) with acute isolated syndesmosis injuries treated with a suture-button system between January 2006 and June 2014, with a mean follow-up of 5.1 ± 2.6 years. Postoperatively, the median FADI score was 136 (range, 78-136), and the median AOFAS score was 100 (range, 87-100). Seventeen (89.5%) patients reported to have reached their preinjury level of sports activities. MRIs of 16 patients were obtained and all showed intact anterior and posterior syndesmotic ligaments; however, in most patients, the previously injured syndesmotic ligament was thickened compared with the uninjured ankle. Average width of the anterior (P = .81) and posterior (P = .60) syndesmosis was not significantly different between the ipsilateral (3.2 ± 1.2 and 4.4 ± 0.9 mm) and contralateral ankles (3.0 ± 0.6 and 4.2 ± 0.7 mm). The median AOSS score was 1.5 (range, 0-11) for the ipsilateral ankle and 0 (range, 0-6) for the contralateral ankle. T2 values of articular cartilage did not significantly differ between the involved and the uninjured ankle (P = .68). Five patients needed hardware removal due to persistent skin irritation, and 1 patient suffered from reinstability of the ankle resulting in revision surgery 2 years after the index surgery. CONCLUSION Suture-button fixation is an excellent treatment for acute and isolated syndesmosis injuries, resulting in stable ankles without early or advanced osteoarthritic changes at midterm follow-up.
منابع مشابه
A Novel Suture Button Construct for Acute Ankle Syndesmotic Injuries; A Prospective Clinical and Radiological Analysis.
Background: The importance of the syndesmosis in ankle stability is well recognized. Numerous means of fixation have been described for syndesmotic injuries including the suture button technique. Significant cost limits the use the commercially available options. We, therefore, designed a cheap and readily available alternative construct. We aim to assess the results of using a novel suture-...
متن کاملA systematic review of suture-button versus syndesmotic screw in the treatment of distal tibiofibular syndesmosis injury
BACKGROUND Now, using a suture-button device to treat distal tibiofibular syndesmotic injuries is overwhelming due to its advantages over screw fixation. Current systematic review was conducted to make a comparison between suture-button fixation and traditionally screw fixation in the treatment of syndesmotic injuries. The outcomes included functional outcomes, implant removal, implant failure,...
متن کاملFlexible stabilization of the distal tibiofibular syndesmosis: clinical and biomechanical considerations: a review of the literature
Syndesmotic rupture is present in 10 % of ankle fractures and must be recognized and treated to prevent late complications. The method of fixation is classically rigid fixation with one or two screws. Knowledge of the biomechanics of the syndesmosis has led to the development of new dynamic implants to restore physiologic motion during walking. One of these implants is the suture-button system....
متن کاملSuture Button Fixation for Syndesmosis Injuries: Review of the Literature
Syndesmosis injuries -also known as high ankle sprainshave an increasing popularity because of an increased awareness of diagnosis. Different from lateral ankle sprains, mechanism of injury mostly involves external rotation, eversion and excessive dorsiflexion. Other mechanisms can also cause sydesmosis injuries. Because of high levels of missed injuries the real prevalence of syndesmosis injur...
متن کاملWeber C ankle fractures with tibiofibular diastasis: syndesmosis-only fixation
OBJECTIVES To evaluate syndesmosis-only fixation in Weber C ankle fractures with tibiofibular diastasis and to assess the need for additional fibular fixation. METHODS Twenty-one patients with Weber C ankle fractures and tibiofibular diastasis were followed for at least 24 months after treatment. In treatment of the Weber C fractures, only a syndesmosis screw was used through a mini open late...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 5 شماره
صفحات -