PURPOSE Tonometry is widely used as the main screening tool supporting glaucoma diagnosis. Still, its accuracy could be improved if full knowledge about the variation of the corneal biomechanical properties was available. In this study, Optical Coherence Tomography (OCT) speckle statistics are used to infer the organisation of the corneal micro-structure and hence, to analyse its influence on intraocular pressure (IOP) measurements. METHODS Fifty-six subjects were recruited for this prospective study. Macro and micro-structural corneal parameters as well as subject age were considered. Macro-structural analysis included the parameters that are associated with the ocular anatomy, such as central corneal thickness (CCT), corneal radius, axial length, anterior chamber depth and white-to-white corneal diameter. Micro-structural parameters which included OCT speckle statistics were related to the internal organisation of the corneal tissue and its physiological changes during lifetime. The corneal speckle obtained from OCT was modelled with the Generalised Gamma (GG) distribution that is characterised with a scale parameter and two shape parameters. RESULTS In macro-structure analysis, only CCT showed a statistically significant correlation with IOP (R2 = 0.25, p<0.001). The scale parameter and the ratio of the shape parameters of GG distribution showed statistically significant correlation with IOP (R2 = 0.19, p<0.001 and R2 = 0.17, p<0.001, respectively). For the studied group, a weak, although significant correlation was found between age and IOP (R2 = 0.053, p = 0.04). Forward stepwise regression showed that CCT and the scale parameter of the Generalised Gamma distribution can be combined in a regression model (R2 = 0.39, p<0.001) to study the role of the corneal structure on IOP. CONCLUSIONS We show, for the first time, that corneal micro-structure influences the IOP measurements obtained from noncontact tonometry. OCT speckle statistics can be employed to learn about the corneal micro-structure and hence, to further calibrate the IOP measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Influence of topical anesthesia on tonometric values of intraocular pressure.

The air pulse noncontact tonometer provides a safe and reliable method for measuring intraocular pressure (IOP), and makes it possible to avoid topical anesthesia. Based on previous reports that suggested possible anesthetic-induced IOP variations, this study was undertaken to investigate with this procedure the influence of local anesthetics on IOP and of some topically used drugs that could m...

متن کامل

Unilateral lattice corneal dystrophy in a young female: A unique case report.

BACKGROUND Unilateral lattice corneal dystrophy is a rare entity. OBJECTIVE To highlight the evidence of unilateral lattice corneal dystrophy in a young female. CASE A young 28 years old female presented to the outpatient department of Ophthalmology with slowly progressive diminution of vision in left eye for one month. On ophthalmological examination best corrected visual acuity (BCVA) was...

متن کامل

Central Corneal Thickness in Spectral-Domain OCT and Associations with Ocular and Systemic Parameters

Background. Optical coherence tomography (OCT) allows quantitative analysis of the anterior segment of the eye with a noncontact examination. The aim of this study is to analyze associations of central corneal thickness (CCT) as measured by OCT with ocular and systemic cardiovascular parameters. Methods. A cross-sectional study of 734 persons was performed in a working age population. Only heal...

متن کامل

Pachymetry before or after applanation tonometry: does it matter?

We examined prospectively 60 healthy volunteers to evaluate if the accuracy of central corneal thickness (CCT) measurement is influenced by Goldmann applanation tonometry (GAT) and vice versa. The sequence of the examinations in the right eye was CCT--GAT--CCT, in the left eye GAT--CCT--GAT and the measurements were done consecutively. Two tonometry and five pachymetry measurements were average...

متن کامل

Diurnal variation of axial length, intraocular pressure, and anterior eye biometrics.

PURPOSE To investigate the diurnal variation in axial length and anterior eye biometrics, while simultaneously measuring intraocular pressure (IOP) with dynamic contour tonometry in human subjects. METHODS Fifteen young adult near-emmetropic subjects had axial length, anterior eye biometrics (central corneal thickness and anterior chamber dimensions), and IOP measured at six different times a...