Scharioth Macula Lens: A new intraocular implant for low-vision patients with stabilized maculopathy- first experience.

نویسندگان

  • Jana Nekolova
  • Pavel Rozsival
  • Martin Sin
  • Nada Jiraskova
چکیده

AIMS To present the initial results of Scharioth Macula Lens (SML) implantation. The SML is a new add-on intraocular lens designed to increase uncorrected near visual acuity (UCVA) in patients with stabilized maculopathy. METHODS Eight patients were included in the study. All met the indication criteria before SML implantation. An SML was implanted in the better seeing eye. Near and distance visual acuity were tested. Possible complications and patient complaints were recorded and patients were asked about their quality of vision after SML implantation. The examination was carried out on day 1, 1 week, 1, 3 and 6 months after surgery. RESULTS Six-month-results are presented. Apart from one, all patients with the SML had good near visual acuity at a recommended reading distance of 15 cm. Preoperatively, the mean (min-max) near UCVA was J13 (J8-J16), mean distance BCVA was 0.27. Postoperatively, the best results were after 1 month - near UCVA was J2.5 (J1-J7), distance BCVA was 0.26. Three months after surgery, this decreased to J4.5 (J1-J8); distance VA remained 0.25. Six months postoperatively - near vision was J4 (J1-J8) and distance VA was unchanged. Patients reported problems with reading speed and reading distance. Daily exercise improved their reading ability. One patient converted to wet AMD 3 months post-implantation. CONCLUSION The SML is a new hope for low-vision patients. It acts as a magnifier in the eye. It is a suitable method for increasing near visual acuity in patients with inactive maculopathy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New add-on intraocular lens for patients with age-related macular degeneration.

UNLABELLED We present a new option for visual rehabilitation of patients with advanced macular degeneration and evaluate the outcomes in the first 8 patients who had implantation of the ciliary sulcus-fixated macular add-on intraocular lens (IOL) (Scharioth Macula Lens) at our institute. The surgical technique for implantation of the add-on IOL is described. Near vision improved in 7 eyes and w...

متن کامل

Paracentral Acute Middle Maculopathy in Birdshot Chorioretinopathy: a Novel Association.

BACKGROUND/PURPOSE To present a novel case of paracentral acute middle maculopathy in association with birdshot chorioretinopathy. METHODS Case report. RESULTS A patient presented with decreased vision and findings of uveitis, vasculitis and a paracentral scotoma. Multimodal imaging was consistent with paracentral acute middle maculopathy in the setting of a multifocal chorioretinopathy and...

متن کامل

Profound hypotony maculopathy in a first episode of bilateral idiopathic acute anterior uveitis

BACKGROUND We report a case of a HLA-B27 negative patient presenting with severe, bilateral, idiopathic acute anterior uveitis with acute hypotony and hypotony maculopathy as their first uveitic episode. CASE PRESENTATION Within a week of onset of her first episode of acute anterior uveitis, a 45 year-old Caucasian lady developed profound ocular hypotony with unrecordable intraocular pressure...

متن کامل

بررسی تأثیر اعمال جراحی پیوند ثانویه عدسی داخل چشمی

Background and purpose : Many aphahic patients have unfavorable vision either with glasses or contact lens. In this study Visual outcome of Seconary (I.O.L) was implantation in aphakic patients referred to Imam Hossein Haspital 1994 evaluated. Materials and Methods : In a clinical trial with sequential sampling , 30 aphakic patients (26 males , 4 females mean of age 24.4 ± 10.8 years) who...

متن کامل

Appearance of age related maculopathy after cataract surgery.

The pathogenesis of age-related maculopathy (ARM), the most common cause of visual loss after the age of 60 years, involves a variety of hereditary and environmental factors. When the cataractous lens is removed and replaced by clear intraocular lens, a significant increase in ocular transmittance of optical radiation occurs. The aim of this study was to assess whether cataract surgery in older...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biomedical papers of the Medical Faculty of the University Palacky, Olomouc, Czechoslovakia

دوره 161 2  شماره 

صفحات  -

تاریخ انتشار 2017