Forces acting on the maxillary incisor teeth during laryngoscopy using the Macintosh laryngoscope.
نویسندگان
چکیده
We determined the forces on the maxillary incisors during routine laryngoscopy in 65 adult patients. The forces were measured by a strain gauge based sensor positioned between the handle and the blade of the laryngoscope. The mean maximal force acting on the maxillary incisors was 49 N. In patients without maxillary incisors, the force acting on the gums was significantly lower at 21 N (p < 0.001). These results suggest that, despite traditional advice to the contrary, a levering movement of the laryngoscope, using the maxillary incisors (or gums) as a fulcrum, is common practice. Biomechanical analysis revealed that, although levering is not the preferred movement, it is an efficient way of bringing the glottis into view. These results may have implications for future laryngoscope design.
منابع مشابه
An evaluation of a modified Macintosh laryngoscope in a manikin.
PURPOSE In this manikin study a modified Macintosh blade was prospectively compared with its original focussing on the forces exerted on the maxillary incisor teeth and intubation success. The modified blade, a standard Macintosh blade with a reduced proximal flange, was intended to reduce the forces exerted on the maxillary incisors. METHODS A manikin equipped with two sensors, to measure fo...
متن کاملDoes experience influence the forces exerted on maxillary incisors during laryngoscopy? A manikin study using the Macintosh laryngoscope.
The influence of the level of experience of the laryngoscopist on the duration of laryngoscopy, the forces exerted on the tongue and on the maxillary incisors during laryngoscopy, were investigated. Five groups (anaesthetists, residents in anaesthesia, nurse anaesthetists, surgeons and medical students), each consisting of 15 individuals, participated in the study. An intubation manikin was use...
متن کاملReshaping the Macintosh blade using biomechanical modelling. A prospective comparative study in patients.
It has been demonstrated that during routine use of the Macintosh blade, great forces are exerted on the maxillary incisors. The aim of this study was, by using biomechanical modelling, to modify a standard Macintosh blade in order to reduce these forces. This resulted in a Macintosh blade with a reduced proximal flange. Five anaesthetists performed tracheal intubation in 46 patients using the ...
متن کاملبررسی شیوع آسیب به دندانها حین لولهگذاری تراشه بوسیله لارینگوسکوپ مکینتاش استاندارد در مقایسه با لارینگوسکوپ مکینتاش تغییریافته
ABSTRACT The Macintosh Laryngoscope has proved itself over half a century and is still one of the most popular laryngoscopes. Even in experienced hands, however, complications can occur notably damage to the maxillary incisors. Damage to teeth is reported to be the most common single reason for complaints against anesthesiologists. Dental injuries could be caused by friction or by contac...
متن کاملAn investigation on stress distribution of the anterior maxillary teeth PDL during the application of intrusive forces in midline
An investigation on stress distribution of the anterior maxillary teeth PDL during the application of intrusive forces in midline Dr. S.M. Abtahi * - Dr. F. Heravi** * - Assistant professor of Orthodontics Dept. Faculty of Dentistry Hamedan University of Medical Sciences. ** - Assistant professor of Orthodontics Dept. Faculty of Dentistry Mashhad University of Medical Sciences. Background an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Anaesthesia
دوره 49 12 شماره
صفحات -
تاریخ انتشار 1994