Permissive hypotension does not reduce regional organ perfusion compared to normotensive resuscitation: animal study with fluorescent microspheres
نویسندگان
چکیده
INTRODUCTION The objective of this study was to investigate regional organ perfusion acutely following uncontrolled hemorrhage in an animal model that simulates a penetrating vascular injury and accounts for prehospital times in urban trauma. We set forth to determine if hypotensive resuscitation (permissive hypotension) would result in equivalent organ perfusion compared to normotensive resuscitation. METHODS Twenty four (n=24) male rats randomized to 4 groups: Sham, No Fluid (NF), Permissive Hypotension (PH) (60% of baseline mean arterial pressure - MAP), Normotensive Resuscitation (NBP). Uncontrolled hemorrhage caused by a standardised injury to the abdominal aorta; MAP was monitored continuously and lactated Ringer's was infused. Fluorimeter readings of regional blood flow of the brain, heart, lung, kidney, liver, and bowel were obtained at baseline and 85 minutes after hemorrhage, as well as, cardiac output, lactic acid, and laboratory tests; intra-abdominal blood loss was assessed. Analysis of variance was used for comparison. RESULTS Intra-abdominal blood loss was higher in NBP group, as well as, lower hematocrit and hemoglobin levels. No statistical differences in perfusion of any organ between PH and NBP groups. No statistical difference in cardiac output between PH and NBP groups, as well as, in lactic acid levels between PH and NBP. NF group had significantly higher lactic acidosis and had significantly lower organ perfusion. CONCLUSIONS Hypotensive resuscitation causes less intra-abdominal bleeding than normotensive resuscitation and concurrently maintains equivalent organ perfusion. No fluid resuscitation reduces intra-abdominal bleeding but also significantly reduces organ perfusion.
منابع مشابه
Ideal permissive hypotension to resuscitate uncontrolled hemorrhagic shock and the tolerance time in rats.
BACKGROUND Studies have shown that permissive hypotension for uncontrolled hemorrhagic shock can result in good resuscitation outcome. The ideal target mean arterial pressure (MAP) and the tolerance time for permissive hypotension have not been determined. METHODS To elucidate the ideal target MAP and tolerance time for permissive hypotension with uncontrolled hemorrhagic shock rats, the effe...
متن کاملPermissive hypotension/hypotensive resuscitation and restricted/controlled resuscitation in patients with severe trauma
Achieving a balance between organ perfusion and hemostasis is critical for optimal fluid resuscitation in patients with severe trauma. The concept of “permissive hypotension” refers to managing trauma patients by restricting the amount of resuscitation fluid and maintaining blood pressure in the lower than normal range if there is continuing bleeding during the acute period of injury. This trea...
متن کاملValidation of fluorescent-labeled microspheres for measurement of regional organ perfusion.
Estimations of dog lung, pig heart, and pig kidney regional perfusion by use of fluorescent-labeled microspheres were compared with measurements obtained with standard radiolabeled microspheres. Pairs of radio- and fluorescent-labeled microspheres (15 microns diam, 6 colors) were injected into a central vein of a supine anesthetized dog and the left ventricle of three supine anesthetized pigs w...
متن کاملShort-term, mild hypothermia can increase the beneficial effect of permissive hypotension on uncontrolled hemorrhagic shock in rats.
BACKGROUND Our previous and other studies have shown that hypotensive or hypothermic resuscitation have beneficial effects on uncontrolled hemorrhagic shock. Whether hypothermia can increase the beneficial effect of hypotensive resuscitation on hemorrhagic shock is not known. METHODS Two-hundred and twenty Sprague-Dawley rats were used to make uncontrolled hemorrhagic shock. Before bleeding w...
متن کاملCorpuls CPR Generates Higher Mean Arterial Pressure Than LUCAS II in a Pig Model of Cardiac Arrest
According to the European Resuscitation Council guidelines, the use of mechanical chest compression devices is a reasonable alternative in situations where manual chest compression is impractical or compromises provider safety. The aim of this study is to compare the performance of a recently developed chest compression device (Corpuls CPR) with an established system (LUCAS II) in a pig model. ...
متن کامل